Series AMEL5-JZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
• Operating Temp: -25 °C to +70 °C
• Input: 85-305VAC, 47-440Hz, or 100-430VDC
• Over current, Over Voltage Protection
• High efficiency up to 83%
• No load consumption ≤ 0.3W
• Ultra small package
• Short Circuit Protection
Models
Single output
Model
AMEL5-3.3SJZ
AMEL5-5SJZ
AMEL5-9SJZ
AMEL5-12SJZ
AMEL5-15SJZ
AMEL5-24SJZ
Input Voltage Input Voltage
(VAC/Hz)
(VDC)
85-305/47-440
85-305/47-440
85-305/47-440
85-305/47-440
85-305/47-440
85-305/47-440
100-430
100-430
100-430
100-430
100-430
100-430
Output
Voltage
(V)
3.3
5
9
12
15
24
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Recommended slow blow type
No load (110/230VAC)
Output
Current max
(A)
1.25
1
0.55
0.42
0.333
0.23
Typical
10
20
1
Maximum
capacitive
Load
(µF)
4000
4000
1000
820
820
330
Maximum
120
70
0.2
0.3
Efficiency
(%)
230
VAC
74
78
78
80
82
83
Units
mA
mA
A
A
mA
A
W
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise *
Hold-up time (minimum)
Conditions
3.3V output
Others
10-100% load
20MHz Bandwidth, 3.3 / 5V models
20MHz Bandwidth, others
115VAC
230VAC
Typical
±3
±2
±0.5
±1
60
50
12
80
Maximum
120
100
Units
%
%
%
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
4000
>1000
Rated
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Protection class
Over Current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
www.aimtec.com
F 052e R8
Conditions
Auto recovery
See derating curve
Typical
Maximum
140
Class II
≥110
Zener diode clamp
Continuous, Auto recovery
-25 to 70°C
-25 to +105
Units
KHz
% of Iout
°C
°C
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)