English
Language : 

AMEL12-CJZ Datasheet, PDF (1/3 Pages) AIMTEC – Continuous Short Circuit Protection
Picture coming soon
FEATURES:
Click on Series name for product info on aimtec.com
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
• I/O Isolation 4000VAC
• Operating Temp: -25°C to +70°C
• Low no load consumption ≤0.3W
• Continuous Short Circuit Protection
• Over current, Over Voltage
• Up to 83% efficiency
• Input: 85-264VAC, 47-440Hz, or 100-370VDC • Low ripple and noise
Models
Single output
Model
Input Voltage
(VAC/Hz)
AMEL12-3.3SCJZ
85-264/47-440
AMEL12-5SCJZ
85-264/47-440
AMEL12-15SCJZ
85-264/47-440
AMEL12-24SCJZ
85-264/47-440
*Output power must not exceed the listed values.
Input
Voltage
(VDC)
100-370
100-370
100-370
100-370
Max
Output
wattage
(W )
7.9
12
12
12
Output
Voltage
(V)
3.3
5
15
24
Output
Current
max (A)
2.4
2.4
0.8
0.5
Maximum
capacitive
load
(µF)
10,000
10,000
2,700
1,500
Efficiency
(%)
74
78
82
83
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Conditions
115VAC
230VAC
115VAC
230VAC
slow blow type
No Load
Typical
0.28
0.19
10
20
3.15
Maximum
0.25
≤0.3
Units
A
A
A
A
mA
A
W
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold up time
Conditions
3.3V output
Others
Full load
10-100% load
20MHz bandwidth
115VAC
230VAC
Typical
±3
±2
±0.5
±1
24
120
Maximum
100
Units
%
%
%
mV p-p
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
60 sec
Typical
>1000
Rated
4000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Operating temperature
Maximum case temperature
www.aimtec.com
F 052e R8
Conditions
100% load
Auto recovery
See derating table
Typical
100
Class II
≥110
Zener Diode Clamp
Continuous
Auto recovery
-25 to +70
Tel: +1 514 620 2722
1 of 3
Maximum
Units
KHz
% of Iout
oC
100
oC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only