English
Language : 

AMEL10-AZ_16 Datasheet, PDF (1/5 Pages) AIMTEC – 10 Watt | AC-DC / DC-DC Converter
Click on Series name for product info on aimtec.com
Series AMEL10-AZ
10 Watt | AC-DC / DC-DC Converter
FEATURES:
 I/O Isolation 3000VAC
 RoHS Compliant
 Operating Temp: -40 oC to +80 oC
 Energy Star Compliant
 Input: 90-305VAC, 47-440Hz, or 130-430VDC  Efficiency up to 83%
 Over Load, Over Voltage, Short Circuit Protection  Soft Start
Models
Single output
CB
Model
AMEL10-3.3SAZ
AMEL10-5SAZ
AMEL10-12SAZ
AMEL10-15SAZ
AMEL10-24SAZ
Input
Voltage
(VAC/Hz)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
Input
Voltage
(VDC)
130-430
130-430
130-430
130-430
130-430
Temperature
range
(ºC)
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
Output
Voltage
(V)
3.3
5
12
15
24
Output
Current
max (A)
3.00
2.00
0.84
0.67
0.42
Maximum
capacitive
Load
(µF)
2200
1000
680
470
470
Efficiency
(%)
115 230 277
VAC VAC VAC
75 74 73
77 75 74
83 82 81
83 81 80
82 81 79
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL10-5SAZ-ST)
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Recommended slow blow type
(110/230/277 VAC)
Typical







1
≦0.2
50
Maximum
230
150
140
20
35
50
0.25
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
±2
Line regulation
±1
Load regulation
0-100% load
±2
Transient recovery time
500
Transient response deviation
25% load step
±2
3.3/5V models
75
Ripple & Noise*
12/15V models
100
24V models
150
Hold-up time
15
* Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
Maximum
Units
%
%
%
µs
% of Vout
mV p-p
mV p-p
mV p-p
ms
Rated
3000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
www.aimtec.com
F 052e R8.K
Conditions
Foldback
Typical
66
130
Zener Diode Clamp
Tel: +1 514 620 2722
1 of 5
Maximum
Units
KHz
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only