English
Language : 

AMEC15-MAZ_12 Datasheet, PDF (1/5 Pages) AIMTEC – 15 Watt | AC-DC / DC-DC Converter
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
Models
Single output
Model
AMEC15-3.3SMAZ
AMEC15-5SMAZ
AMEC15-12SMAZ
AMEC15-15SMAZ
AMEC15-24SMAZ
FEATURES:
• Connector on Input & Output
• Operating temperature: -40 to +80°C
• Over load, Over Voltage, Short Circuit Protection
• Optional DIN Rail mounting bracket
• Universal input: 90-264VAC, 47-440Hz
• RoHS compliant
• Soft start
• Energy Star compliant
• CE, cULus, CB approvals
• 4000VAC I/O Isolation
CB
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
Input voltage
(VDC)
120-370
120-370
120-370
120-370
120-370
Output
Voltage
(V)
3.3
5
12
15
24
Output
Current
max (A)
3
3
1.25
1
0.63
Maximum
Capacitive Load
(µF)
4700
2200
1000
680
470
Efficiency
(%)
74
78
81
81
83
Models
Dual output
Model
AMEC15-5DMAZ
AMEC15-12DMAZ
AMEC15-15DMAZ
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
Input voltage
(VDC)
120-370
120-370
120-370
Output
Voltage
(V)
±5
±12
±15
Output
Current
max (A)
±1.5
±0.63
±0.5
Maximum
Capacitive Load
(µF)
±1000*
±470*
±330*
Efficiency
(%)
78
80
81
Input Specifications
Parameters
Current
Inrush current <2ms
Leakage current
External Fuse (recommend)
Input Dissipation
Under Voltage Protection
Conditions
115VAC
230VAC
115 VAC
230 VAC
115 VAC
264 VAC
slow blow type
No load
Typical
2
<0.5
88
Maximum
350
180
10
20
0.1
0.2
Units
mA
mA
A
A
mA
mA
A
W
VAC
Output Specifications
Parameters
Conditions
Voltage accuracy
Line regulation
LL-HL
Load regulation (single output)
Cross regulation (dual output)
0-100%
25% load - 1st out, 100% load – 2nd out
Transient Recovery Time
Transient Recovery Deviation
25% load step
Ripple & Noise*
20MHz bandwidth
Hold-up time
min
*Ripple & Noise measured with 1μF M/C and 47μF E/C
Typical
±2
±0.5
±0.5
±5
200
±2
100
20
Maximum
Units
%
%
%
%
µs
% of Vout
mVp-p
ms
www.aimtec.com
F 052e R8.P
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only