English
Language : 

AME60-MJZ Datasheet, PDF (1/5 Pages) AIMTEC – 60 Watt | AC-DC / DC-DC Converter
Picture coming soon
FEATURES:
Click on Series name for product info on aimtec.com
Series AME60-MJZ
60 Watt | AC-DC / DC-DC Converter
Models
Single output
Model
AME60-5SMJZ
AME60-9SMJZ
AME60-12SMJZ
AME60-15SMJZ
AME60-24SMJZ
AME60-48SMJZ
 I/O Isolation 4000VAC
 Input under-voltage protection
 Input: 90-264VAC/47-63Hz, or 122-370VDC
 Over current, Over Voltage Protection
 Continuous Short circuit protection
 Low no load consumption ≤0.5W
 Efficiency up to 86%
 Output Voltage adjustment
Input Voltage
(VAC/Hz)
90-264/47-63
90-264/47-63
90-264/47-63
90-264/47-63
90-264/47-63
90-264/47-63
Input Voltage
(VDC)
122-370
122-370
122-370
122-370
122-370
122-370
Output
Voltage
(V)
5
9
12
15
24
48
Output
Current max
(A)
10
6.6
5
4
2.5
1.25
Maximum
capacitive
Load
(µF)
80,000
28,000
14,000
12,000
4000
1000
Efficiency
230VAC
(%)
82
84
86
86
86
86
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Under voltage protection
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Shutdown
Typical


30
50
Maximum
1.4
0.7
75
105
Units
A
A
A
A
VAC
VDC
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold-up time
Voltage adjustment range
Conditions
Full load
LL-HL, Full Load
5-100% load
20MHz bandwidth
115VAC
230VAC
Single output only
Typical
±2
±0.5
±1
15
80
Maximum
150
±10
Units
%
%
%
mV p-p
ms
ms
% of Vout
Isolation Specifications
Parameters
Tested I/O voltage
Isolation voltage Input to Ground
Isolation voltage Output to Ground
Conditions
60 sec
60 sec
60 sec
Typical
Rated
4000
1500
500
Units
VAC
VAC
VAC
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Temperature coefficient
Cooling
www.aimtec.com
F 052e R8.A
Conditions
100% load
See derating curve
Free air convection
Typical
100
Class I
≥110
Zener diode clamp
Continuous, Auto recovery
-40 to +70
-40 to +85
±0.02
Maximum
100
Units
KHz
% of Iout
oC
oC
oC
% / oC
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only