English
Language : 

AME3-5SAZ Datasheet, PDF (1/3 Pages) AIMTEC – AC-DC Converter
Click on Series name for product info on aimtec.com
FEATURES:
Series AME3-AZ
3Watt | AC-DC Converter
Models
Single output
Model
AME3-3.3SAZ
AME3-5SAZ
AME3-12SAZ
AME3-15SAZ
AME3-24SAZ
AME3-3.3SBAZ
AME3-5SBAZ
AME3-12SBAZ
AME3-15SBAZ
AME3-24SBAZ
• I/O Isolation 3000VAC
• Operating Temp: -40oCto +80oC
• Over load, Short Circuit Protection
• Input: 90-305VAC, 47-440Hz, or 130-430 VDC
• Optional 90-528VAC, 47-440Hz, or 130-745 VDC
• RoHS compliant
• Energy Star compliant
• Ultra small package
Input
Voltage
(VAC/Hz)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
Input
Voltage
(VDC)
130-430
130-430
130-430
130-430
130-430
130-745
130-745
130-745
130-745
130-745
Temperature
range
(ºC)
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
Output
Voltage
(V)
3.3
5
12
15
24
3.3
5
12
15
24
Output
Current max
(mA)
900
600
250
200
125
Maximum
capacitive
Load
(µF)
2200
1100
680
560
470
Efficiency
(%)
115 230 277 480
VAC
VAC
VAC
VAC
63 64 62
67 67 65
75 73 70
78 74 71
81 81 80
700
2200
61 61 60 54
600
1100
67 67 66 60
250
680
72 72 70 61
200
560
72 71 70 61
125
470
71 71 69 62
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Conditions
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Recommended slow blow type
Typical
1
≦0.5
Maximum
80
40
35
30
10
15
20
30
0.15
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Full load (typical)*
±5
Line regulation
LL-HL, Full Load
±1.5
Load regulation (single output)
0-100% load (typical)*
±5
Transient Recovery Time
200
Transient Response Deviation
25% load step
±2
Minimum load
0
3.3/5 VAC With 560µF E/C
200
Ripple & Noise
12/15 VAC With 220µF E/C
400
24 VAC With 220µF E/C
500
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1µFand 115/230/277/480VAC( Typical input ) with Full Load
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
Maximum
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Rated
3000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over Load protection
Short circuit protection
www.aimtec.com
F 052e R8.B
Conditions
Auto recovery
Typical
100
>125%
Auto recovery
Tel: +1 514 620 2722
1 of 3
Maximum
Units
KHz
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only