AME15-JZ Datasheet, PDF (1/3 Pages) AIMTEC – 15 Watt | AC-DC / DC-DC Converter | |||
|
FEATURES:
Click on Series name for product info on aimtec.com
Series AME15-JZ
15 Watt | AC-DC / DC-DC Converter
ï· I/O Isolation 3000VAC
ï· Operating Temp: -40°C to +70°C
ï· Over current Protection
ï· Input: 85-305VAC, 47-63Hz, or 100-430VDC
ï· Low Ripple and Noise
ï· Over Voltage Protection
ï· Up to 85% efficiency
ï· Short Circuit Protection
Models
Single output
Model
AME15-3.3SJZ
AME15-5SJZ
AME15-9SJZ
AME15-12SJZ
AME15-15SJZ
AME15-24SJZ
AME15-48SJZ
Input
Voltage
(VAC/Hz)
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
Input
Voltage
(VDC)
100-430
100-430
100-430
100-430
100-430
100-430
100-430
Max
Output
wattage
(W)
9.9
14
15
15
15
15
15
Output
Voltage
(V)
3.3
5
9
12
15
24
48
Output
Current max
(A)
3
2.8
1.6
1.25
1
0.625
0.32
Maximum
capacitive load
(µF)
36000
20000
6000
3000
3000
900
370
Efficiency
(%)
230
VAC
74
78
79
82
82
84
85
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Recommended slow blow type
Typical
10
20
ï
2
Maximum
370
220
0.25
Units
mA
mA
A
A
mA
A
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold-up time
Conditions
(LL-HL)
10-100% load
115 VAC
230 VAC
Typical
±2
±0.5
±1
15
80
Maximum
100
Units
%
%
%
mV p-p
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Input to Output, 60 sec
Input to Ground
Typical
>1000
Rated
3000
2000
Units
VAC
Mâ¦
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Conditions
See derating curve
Typical
Maximum
65
â¥110
Zener Diode Clamp
Auto recovery
-40 to +70
100
-40 to +105
±0.02
Units
KHz
% of Iout
°C
°C
°C
% / °C
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
|
▷ |