FEATURES:
Click on Series name for product info on aimtec.com
Series AME10-JZ
10 Watt | AC-DC / DC-DC Converter
 I/O Isolation 3000VAC
 Operating Temp: -40°C to +70°C
 Over current Protection
 Input: 85-305VAC, 47-63Hz, or 100-430VDC
 Low Ripple and Noise
 Over Voltage Protection
 Up to 82% efficiency
 Short Circuit Protection
Models
Single output
Model
AME10-3.3SJZ
AME10-5SJZ
AME10-9SJZ
AME10-12SJZ
AME10-15SJZ
AME10-24SJZ
Input
Voltage
(VAC/Hz)
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
Input
Voltage
(VDC)
100-430
100-430
100-430
100-430
100-430
100-430
Max
Output
wattage
(W)
6.6
10
10
10
10
10
Output
Voltage
(V)
3.3
5
9
12
15
24
Output
Current max
(A)
2
2
1.1
0.9
0.7
0.45
Maximum
capacitive load
(µF)
26000
9400
3600
2400
1200
370
Efficiency
(%)
230
VAC
70
76
78
80
81
82
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Recommended slow blow type
Typical
10
15

2
Maximum
260
160
0.25
Units
mA
mA
A
A
mA
A
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold-up time
Conditions
(LL-HL)
10-100% load
115 VAC
230 VAC
Typical
±2
±0.5
±1
15
80
Maximum
100
Units
%
%
%
mV p-p
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Input to Output, 60 sec
Input to Ground
Typical
>1000
Rated
3000
2000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Conditions
See derating curve
Typical
Maximum
100
≥110
Zener Diode Clamp
Auto recovery
-40 to +70
100
-40 to +105
±0.02
Units
KHz
% of Iout
°C
°C
°C
% / °C
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only