English
Language : 

AME1-5SAZ Datasheet, PDF (1/3 Pages) AIMTEC – AC-DC Converter
Models
Single output
Model
AME1-3.3SAZ
AME1-5SAZ
AME1-12SAZ
AME1-15SAZ
AME1-24SAZ
AME1-3.3SBAZ
AME1-5SBAZ
AME1-12SBAZ
AME1-15SBAZ
AME1-24SBAZ
Click on Series name for product info on aimtec.com
FEATURES:
Series AME1-AZ
1Watt | AC-DC Converter
• I/O Isolation 3000VAC
• Operating Temp: -40°C to +80°C
• Input: 90-305VAC, 47-440Hz, or 130-430 VDC
• Optional 90-528VAC, 47-440Hz, or 130-745 VDC
• Over load, Short Circuit Protection
• RoHS compliant
• Energy Star compliant
• Ultra small package
Input
Voltage
(VAC/Hz)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
Input
Voltage
(VDC)
130-430
130-430
130-430
130-430
130-430
130-745
130-745
130-745
130-745
130-745
Temperature
range
(ºC)
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
Output
Voltage
(V)
3.3
5
12
15
24
3.3
5
12
15
24
Output
Current max
(mA)
300
200
83
67
42
Maximum
capacitive
Load
(µF)
2200
1100
680
560
470
Efficiency
(%)
115 230 277 480
VAC
VAC
VAC
VAC
62 59 58
58 57 56
73 68 65
77 68 70
79 79 77
300
2200
51 51 50 44
200
1100
57 57 56 50
83
680
62 62 60 51
67
560
61 59 58 50
42
470
58 58 56 48
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Conditions
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Recommended slow blow type
Typical
1
≦0.5
Maximum
25
20
15
5
10
15
20
30
0.15
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Ripple & Noise
Conditions
Full load (typical)*
LL-HL, Full Load
0-100% load (typical)*
25% load step
3.3/5 VAC With 560µF E/C
12/15 VAC With 220µF E/C
24 VAC With 220µF E/C
Typical
±5
±1.5
±5
200
±2
0
200
400
500
*Ripple &Noisemeasuredat 20MHz bandwidth with 0.1µFand 115/230/277/480 VAC( Typical input ) with Full Load
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
www.aimtec.com
F 052e R8.B
Tel: +1 514 620 2722
1 of 3
Maximum
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Rated
3000
Units
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only