English
Language : 

AM40U-AZ_16 Datasheet, PDF (1/4 Pages) AIMTEC – 40 Watt | DC-DC Converter
Click on Series name for product info on aimtec.com
FEATURES:
Series AM40U-AZ
40 Watt | DC-DC Converter
 Wide Input 2:1 Range

 Full Internal SMD Technology 
 1600 VDC Isolation

 Efficiency up to 89%

Adjustable Output Voltage
Remote ON/OFF Function
Over Load, Voltage & Short Circuit Protection
Operating temperature -40oC to + 85oC
Models
Single output
Model
AM40U-1203SAZ
AM40U-1205SAZ
AM40U-1212SAZ
AM40U-1215SAZ
AM40U-2403SAZ
AM40U-2405SAZ
AM40U-2412SAZ
AM40U-2415SAZ
AM40U-4803SAZ
AM40U-4805SAZ
AM40U-4812SAZ
AM40U-4815SAZ
Input Voltage
(V)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
Output Voltage
(V)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
Output Current
max (A)
8
8
3.3
2.6
8
8
3.3
2.6
8
8
3.3
2.6
Isolation
(VDC)
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
Efficiency
(%)
85
86
86
87
86
88
88
89
87
88
89
89
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Input reflected ripple current
Remote CNTL (ON/OFF)
Nominal
Typical
Maximum
12
9-18
24
18-36
48
36-75
π(Pi) Network
25
12
36
24
50
48
100
100
20
ON – Open or without any connection or 3.5V ≤ 12V
OFF- Short to input ground or 0V ൑ 1.2V
Units
VDC
ms
VDC
ms
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3 sec
Typical
>1000
220
Rated
1600
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Thermal shutdown
www.aimtec.com
F 051e R12.G
Conditions
Foldback
On Case
Typical
±2
Zener Diode Clamp
135~150
Continuous
Auto-Restart
110
Tel: +1 514 620 2722
1 of 4
Maximum
Units
%
%
ºC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only