English
Language : 

AM2LW-NZ_16 Datasheet, PDF (1/3 Pages) AIMTEC – 1.5 Watt | DC-DC Converter
FEATURES:
Click on Series name for product info on aimtec.com
Series AM2LW-NZ
1.5 Watt | DC-DC Converter
• SMD package
• Ultra Wide (4:1) input range
• 1500VDC isolation
• Continuous short circuit protection
• Operating temperature: -40°C to +85°C
• Regulated single/dual output
• MTBF>1,000,000 hours
• RoHS compliant
Models: Single output
Model
Input Voltage(V)
AM2LW-2403S-NZ
AM2LW-2405S-NZ
AM2LW-2409S-NZ
AM2LW-2412S-NZ
AM2LW-2415S-NZ
AM2LW-4805S-NZ
*AM2LW-4809S-NZ
9-36
9-36
9-36
9-36
9-36
18-72
18-72
Output Voltage
(V)
3.3
5
9
12
15
5
9
Output Current
max(mA)
455
300
167
125
100
300
167
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
Efficiency
(%)
72
76
78
79
80
76
78
Models: Dual output
Model
Input Voltage Output Voltage Output Current
(V)
(V)
max (mA)
AM2LW-2405D-NZ
9-36
±5
±150
AM2LW-2412D-NZ
9-36
±12
±63
AM2LW-2415D-NZ
9-36
±15
±50
*Not recommended for new design
NOTE 1: Add suffix “TR” to a part number when ordering in tape and reel package
Isolation
(VDC)
1500
1500
1500
Efficiency
(%)
74
77
75
NOTE 2: Unless otherwise specified, all specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load.
Input Specifications
Parameters
Voltage range
Absolute Maximum Rating
Peak Input Voltage time
Nominal
24
48
24
48
Typical
9-36
18-72
Maximum
40
80
100
Units
VDC
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec
At 500 Vdc
Input to Output
Typical
1000
1000
Rated
1500
Units
VDC
MOhm
pF
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
±5
Short Circuit protection
Continuous
Short circuit restart
Auto-Recovery
Line voltage regulation
From Low in to High In
±0.75
Load voltage regulation (Single)
From 10% to 100% load
±1.5
Load voltage regulation (Dual)
From 10% to 100% load
Unbalanced load
±5
Temperature coefficient
±0.03
Ripple & Noise
20MHz Bandwidth
100
Minimum Load Current*
10
* Operation under 10% load will not damage the converter; however, not all specifications will be met.
www.aimtec.com
Tel: +1 514 620 2722
F 051e R8.F
1 of 3
Maximum
Units
%
%
%
%
%/oC
mV p-p
% of Max
Toll free: + 1 888 9 AIMTEC
(924 6832)