English
Language : 

AM2LP-NZ Datasheet, PDF (1/3 Pages) AIMTEC – 2 Watt | DC-DC Converter
FEATURES:
• SMD Package
• Single Output Models
• Low Ripple and Noise
• High efficiency up to 81%
Series AM2LP-NZ
2 Watt | DC-DC Converter
• Operating temperature -40oC to + 85oC
• Input / Output Isolation 1000 VDC
• Pin compatible with multiple manufacturers
• RoHS compliant
Models
Single output
Model
AM2LP-0505S-NZ
AM2LP-0512S-NZ
AM2LP-0515S-NZ
AM2LP-1205S-NZ
AM2LP-1212S-NZ
AM2LP-1215S-NZ
AM2LP-2405S-NZ
AM2LP-2412S-NZ
AM2LP-2415S-NZ
AM2LP-2424S-NZ
Input Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
Output Voltage
(V)
5
12
15
5
12
15
5
12
15
24
Output Current
max (mA)
400
167
133
400
167
133
400
167
133
84
Isolation
(VDC)
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Efficiency
(%)
78
79
80
78
80
81
78
80
81
80
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Nominal
5
12
24
Typical
4.5-5.5
10.8-13.2
21.6-26.4
Capacitor
Maximum
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
60 sec
500Vdc
Typical
>1000
Rated
1000
Units
VDC
MOhm
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See the tolerance graph
±5
%
Short Circuit protection
Momentary (1sec)
Line voltage regulation
For 1.0% of Vin
1.2
% of Vin
Load voltage regulation
Temperature coefficient
Load 10 – 100%
10
±0.03
%
%/oC
Ripple & Noise
20MHz Bandwidth
150
mV p-p
Minimum Load Current
10
% of Max
If the operating output current is less than 10% of maximum it is recommended to install a load resistor in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Conditions
100% load
Without derating
Typical
Maximum
500
-40 to +85
-55 to +125
+95
Free air convection
Units
KHz
oC
oC
oC
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only