English
Language : 

AM2GW-NZ_16 Datasheet, PDF (1/2 Pages) AIMTEC – 2 Watt | DC-DC Converter
FEATURES:
• RoHS compliant
• Ultra wide 4:1 input range
• Remote On/Off Control
• 9 pin SIP package
Click on Series name for product info on aimtec.com
Series AM2GW-NZ
2 Watt | DC-DC Converter
• Operating temperature -40oC to + 85oC
• Continuous Short circuit protection
• High efficiency up to 76%
• Low ripple and noise
Models
Single output
Model
AM2GW -2405S-NZ
AM2GW -4805S-NZ
Input
Voltage (V)
9-36
18-72
Output
Voltage
(V)
5
5
Output Current
max
(mA)
400
400
Isolation
(VDC)
1500
1500
Max Capacitive
Load
(μF)
820
820
Efficiency
75
76
Input Specifications
Parameters
Nominal
Typical
Maximum
Voltage range
Filter
24
9-36
48
18-72
Capacitor
Maximum Rating
24 Vin
40
48 Vin
80
Peak Input Voltage time
On/Off Control
100
ON – low or open; OFF – high
On/Off input current
5
10
* Exceeding the maximum permissible value of 20mA for the Input On/Off current will damage the converter.
Isolation Specifications
Parameters
TestedI/O voltage
Resistance
Capacitance
Conditions
60 sec
At 500VDC
Typical
> 1000
80
Rated
1500
Units
VDC
VDC
ms
mA
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Conditions
LL~HL
Load 10~100%
At 20MHz Bandwidth
Typical
±3
Continuous
Auto recovery
±0.75
±1.5
±0.03
100
Maximum
Units
%
%
%
%/oC
mV p-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load, Vin nominal
>100
550
KHz
Operating temperature
With derating above 71oC
-40 to +85
oC
Storage temperature
-50 to +125
oC
Temperature rise
Full load
15
35
oC
Cooling
Free air convection
Humidity
95
%
Case material
Non-conductive black plastic (UL94V-0 rated)
Weight
7
g
Dimensions (L x W x H)
MTBF
1.02 x 0.37x 0.49 inch26.00 x 9.60 x 12.00 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise
specified
www.aimtec.com
F 051e R6.F
Tel: +1 514 620 2722
1 of 2
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only