FEATURES:
Series AM2B-NZ
2 Watt | DC-DC Converter
 6000VDC Isolation
 Low Profile DIP 16 Package
 Industry Standard Pinout
 MTBF>1,000,000 hours
 Unregulated Single Output Models
 Operating temperature: -40°C to +85°C
 High Efficiency up to 85%
 RoHS Compliant
Models
Single output
Model
AM2B-0505SH60-NZ
AM2B-0512SH60-NZ
AM2B-0515SH60-NZ
AM2B-1205SH60-NZ
AM2B-1215SH60-NZ
AM2B-2405SH60-NZ
AM2B-2415SH60-NZ
Input Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
Output Voltage
(V)
5
12
15
5
15
5
15
Output Current
max (mA)
400
167
133
400
133
400
133
Isolation
(VDC)
6000
6000
6000
6000
6000
6000
6000
Efficiency
(%)
76
79
78
76
79
77
78
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
5
12
24
Typical
4.5-5.5
10.8-13.2
21.6-26.4
Maximum
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Capacitance
Resistance
Conditions
60 sec
500VDC
Typical
10
>1000
Rated
6000
Units
VDC
pF
MOhm
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See Tolerance Graph
±5
%
Short circuit protection
Continuous
Short Circuit restart
Auto Recovery
Line voltage regulation
For a 1% change of Vin
±1.2
%
Load voltage regulation
Temperature coefficient
From 10% load to 100% load
At 100% load
12
±0.03
%
%/oC
Ripple & Noise*
20MHz Bandwidth
150
mV p-p
Minimum load current**
10
% of Max
* Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available at www.aimtec.com
** If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
www.aimtec.com
F 051e R12.C
Conditions
Typical
100% load, nominal input
50
-40 to + 85
-55 to + 125
Tel: +1 514 620 2722
1 of 4
Maximum
100
Units
KHz
oC
oC
oC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only