English
Language : 

AM1_4LS-NZ Datasheet, PDF (1/4 Pages) AIMTEC – 0.25 Watt | DC-DC Converter
Click on Series name for product info on aimtec.com
FEATURES:
Series AM1/4LS-NZ
0.25 Watt | DC-DC Converter
 SMD Package
 Single Output Models
 I/O Isolation 1500 & 3000 VDC  Operating temperature -40oC to + 105oC
 Ultra Low Ripple and Noise
 Efficiency up to 79%
 Industry Standard Pinout
 Continuous Short Circuit Protection
Models
Single output
Model
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current
Max | Min
(mA)
Input
Current Full
| No Load
(mA)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
AM1/4LS-0305S-NZ
2.97-3.63
5
50
5
87
20
1500
220
74
AM1/4LS-0503S-NZ
4.5-5.5
3.3
76
8
68
15
1500
220
74
AM1/4LS-0505S-NZ
4.5-5.5
5
50
5
68
15
1500
220
77
AM1/4LS-1205S-NZ
10.8-13.2
5
50
5
27
10
1500
220
75
AM1/4LS-1209S-NZ
10.8-13.2
9
28
3
27
10
1500
220
79
AM1/4LS-1212S-NZ
10.8-13.2
12
21
2
27
10
1500
220
77
AM1/4LS-2405S-NZ
21.6-26.4
5
50
5
15
8
1500
220
69
AM1/4LS-0505SH30-NZ
4.5-5.5
5
50
5
68
15
3000
220
77
AM1/4LS-1205SH30-NZ
10.8-13.2
5
50
5
27
10
3000
220
77
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Absolute Maximum Rating
Peak Input Voltage time
Input Reflected Ripple Current
Nominal
3.3
5
12
24
3.3 Vin
5 Vin
12 Vin
24Vin
3.3 & 5V Input
12 &24 V Input
Typical
2.97-3.63
4.5-5.5
10.8-13.2
21.6-26.4
Capacitor
-0.7-5
-0.7-9
-0.7-18
-0.7-30
1
20
5
Maximum
Units
VDC
VDC
s
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec, <1mA
500VDC
Typical
1500 & 3000
൐1000
20
Maximum
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Conditions
100% load (see tolerance chart)
For ±1% of Vin
10% - 100% load
100% load
20MHz Bandwidth
Typical
±2.5
Continuous
Auto-Recovery
±1.5
15
±0.03
20
Maximum
Units
%
% of Vin
%
%/oC
mV p-p
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)