English
Language : 

AM15EW-NZ Datasheet, PDF (1/4 Pages) AIMTEC – 15 Watt | DC-DC Converter
Picture coming soon
FEATURES:
Series AM15EW-NZ
15 Watt | DC-DC Converter
 Efficiency up to 89%
 On/Off Remote Control
 Ultra wide 4:1 Input range
 Over Voltage Protection
 Continuous short circuit protection
 Input / Output Isolation 1500VDC
 Operating Temperature: -40oC to +85oC  Over Current protection
Models
Single output
Model
Input
Voltage (V)
AM15EW-11003S-NZ
40-160
AM15EW-11005S-NZ
40-160
AM15EW-11012S-NZ
40-160
AM15EW-11015S-NZ
40-160
AM15EW-11024S-NZ
40-160
Add suffix “-K” for optional heat sink
Output
Voltage
(V)
3.3
5
12
15
24
Output Current
max (mA)
4000
3000
1250
1000
625
Isolation
(VDC)
1500
1500
1500
1500
1500
Max
Capacitive
Load(uF)
4020
4020
1600
1000
470
Efficiency
(%)
87
89
88
88
88
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
No load Input Current
Input reflected current
Nominal
Typical
Maximum
Units
110
40-160
VDC
π(Pi) Network
10
ms
110
200
VDC
100
ms
ON – open or 3.5-12VDC ; OFF – short to –Vin or 0-1.2VDC, Idle current 1mA
15
mA
25
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec, 1mA
Typical
1500
>1000
2000
Maximum
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Minimum Load Current
Transient recovery time
Transient recovery deviation
Conditions
Typical
±3
Zener Diode Clamp
130
Continuous
Auto-Recovery
Full load, LL-HL
±0.5
5% to 100% load
±1
20MHz Bandwidth
5
25% load step change
25% load step change
±5
Maximum
170
Units
%
%
% of Io
±0.02
100
±10
800
% of Vin
%
%/oC
mV p-p
%
% of Max
µS
%
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only