English
Language : 

AIC2350 Datasheet, PDF (12/12 Pages) Analog Intergrations Corporation – 400mA Synchronous PWM/PSM Step-Down
 PHYSICAL DIMENSIONS
 SOT-23-5
D
AIC2350
A
A
e
e1
SEE VIEW B
b
WITH PLATING
BASE METAL
SECTION A-A
S
Y
M
B
O
L
A
GAUGE PLANE
A1
SEATING PLANE
A2
L
b
L1
c
VIEW B
D
E
Note : 1. Refer to JEDEC MO-178AA.
E1
2. Dimension "D" does not include mold flash, protrusions
e
or gate burrs. Mold flash, protrusion or gate burrs shall not
e1
exceed 10 mil per side.
L
3. Dimension "E1" does not include inter-lead flash or protrusions. L1
4. Controlling dimension is millimeter, converted inch
θ
dimensions are not necessarily exact.
SOT-23-5
MILLIMETERS
MIN.
0.95
0.00
0.90
0.30
0.08
2.80
2.60
1.50
0.95 BSC
1.90 BSC
0.30
0.60 REF
0°
MAX.
1.45
0.15
1.30
0.50
0.22
3.00
3.00
1.70
0.60
8°
Note:
Information provided by AIC is believed to be accurate and reliable. However, we cannot assume responsibility for use of any circuitry other
than circuitry entirely embodied in an AIC product; nor for any infringement of patents or other rights of third parties that may result from its
use. We reserve the right to change the circuitry and specifications without notice.
Life Support Policy: AIC does not authorize any AIC product for use in life support devices and/or systems. Life support devices or sys-
tems are devices or systems which, (I) are intended for surgical implant into the body or (ii) support or sustain life, and whose failure to
perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a
significant injury to the user.
12