English
Language : 

W3030 Datasheet, PDF (7/22 Pages) Agere Systems – W3030 3 V Dual-Mode IF Cellular Receiver
Data Sheet
April 1999
W3030 3 V Dual-Mode IF Cellular Receiver
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect device reliability.
Parameter
Ambient Operating Temperature
Storage Temperature
Lead Temperature (soldering, 10 s)
Positive Supply Voltage
Power Dissipation
Output Current (continuous)
ac Peak-to-peak Input Voltage
Enable Input Voltage
VCM, AGC Input Voltage
Min
Max
Unit
–35
100
°C
–65
150
°C
—
300
°C
0
4.5
Vdc
—
650
mW
—
160
mA
0
VCC
Vdc
–0.3
VCC + 0.4
Vdc
–0.3
VCC + 0.4
Vdc
Handling Precautions
Although protection circuitry has been designed into this device, proper precautions should be taken to avoid
exposure to electrostatic discharge (ESD) during handling and mounting. Lucent Technologies Microelectronics
Group employs a human-body model (HBM) and a charged-device model (CDM) for ESD-susceptibility testing
and protection design evaluation. ESD voltage thresholds are dependent on the circuit parameters used to define
the model. No industry-wide standard has been adopted for CDM. However, a standard HBM (resistance =
1500 Ω, capacitance = 100 pF) is widely used and, therefore, can be used for comparison purposes. The HBM
ESD threshold presented here was obtained by using these circuit parameters:
W3030 ESD Threshold Voltage
ESD Model
Rating
HBM
≥1500 V
CDM
≥1500 V
Lucent Technologies Inc.
7