English
Language : 

W3013 Datasheet, PDF (6/12 Pages) Agere Systems – W3013 Indirect Quadrature Modulator with Gain Control
W3013 Indirect Quadrature Modulator
with Gain Control
Preliminary Data Sheet
November 1998
Error Vector Magnitude (EVM) Testing
Error vector magnitude (EVM) is estimated by feeding signals to the W3013 as described at the top of the
Electrical Characteristics table. A narrowband, sine-wave modulation output spectrum is shown in Figure 3.
0
–10
USB
–10 dBm
fBB = 80 kHz
fLO1= 178 MHz
fLO2 = 1620 MHz
–20
RFOUT= 1442.08 MHz
–30
–40
CARRIER
LSB –50 dBm
–50
–53 dBm
L3
–61 dBm
–60
L2
–72 dBm
–70
–80
L5
–82 dBm
L4
–81 dBm
U2
–63 dBm
U3
–71 dBm
U5
U4 –77 dBm
–84 dBm
–90
1441.60 1441.68 1441.76 1441.84 1441.92 1442 1442.08 1442.16 1442.24 1442.32 1442.40
FREQUENCY (MHz)
Figure 3. W3013 Sine-Wave Modulation Output Spectrum
Data from this spectrum are used to estimate EVM by the formula:
EVM (%) = 100 • [10P(L5)/20 + 10P(L4)/20 + 10P(L3)/20 + 10P(L2)/20 +
10P(LSB)/20 + 10P(U2)/20 + 10P(U3)/20 + 10P(U4)/20 + 10P(U5)/20 ]/10P(USB)/20
The data presented in the spectrum above would yield:
EVM (%) = 100 Ÿ [79e–6 + 89e–6 + 891e–6 + 251e–6 + 2239e–6 + 708e–6 + 282e–6 + 63e–6 +
141e–6]/0.316e
= 1.5%
This approximates worst-case digital modulation results because the sine-wave modulation estimate assumes all
spurious outputs are in phase and adds their magnitudes as scalars. In addition, this estimate includes full-
amplitude measurements of spurious peaks that would appear in adjacent and alternate channels, where a
receiver would otherwise provide attenuation. The L3 third-order intermodulation peak and LSB (lower sideband)
are normally the unwanted output frequencies that dominate the EVM estimate.
6
Lucent Technologies Inc.