L7582 Datasheet, PDF (6/16 Pages) Agere Systems – Tip Ring Access Switch | |||
|
◁ |
L7582 Tip Ring Access Switch
Data Sheet
November 1999
Electrical Characteristics (continued)
Table 8. Loop Access Switches, 5 and 6
Parameter
OFF-state Leakage
Current:
+25 °C
+85 °C
â40 °C
dc Current Limit:
+85 °C
â40 °C
Dynamic Current Limit
(t = <0.5 µs)
ON-resistance:
+25 °C
+85 °C
â40 °C
ON-state Voltage*
Isolation:
+25 °C
+85 °C
â40 °C
dV/dt Sensitivityâ
Test Condition
Measure
Vswitch (differential) = â320 V to Gnd
Vswitch (differential) = â60 V to +260 V
Vswitch (differential) = â330 V to Gnd
Vswitch (differential) = â60 V to +270 V
Vswitch (differential) = â310 V to Gnd
Vswitch (differential) = â60 V to +250 V
Iswitch
Iswitch
Iswitch
Vswitch (on) = ±10 V
Vswitch (on) = ±10 V
Break switches in ON state; ringing access
switches off; apply ±1000 V at 10/1000 µs pulse;
appropriate secondary protection in place
Iswitch
Iswitch
Iswitch
Iswitch (on) = ±10 mA, ±40 mA
Iswitch (on) = ±10 mA, ±40 mA
Iswitch (on) = ±10 mA, ±40 mA
Iswitch = ILIMIT @ 50 Hz/60 Hz
â VON
â VON
â VON
VON
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
â
Iswitch
Iswitch
Iswitch
â
Min Typ Max Unit
â â 1 µA
â â 1 µA
â â 1 µA
80 â â mA
â â 250 mA
â 2.5 â A
â 45 â â¦
â â 70 â¦
â 33 â â¦
â â 130 V
â â 1 µA
â â 1 µA
â â 1 µA
â 200 â V/µs
* This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
â Applied voltage is 100 Vp-p square wave at 100 Hz.
6