R480 Datasheet, PDF (4/8 Pages) Agere Systems – R480-Type Lightwave Receiver with CML Data Output for up to 2.488 Gbits/s Applications | |||
|
◁ |
R480-Type Lightwave Receiver with CML Data Output
for up to 2.488 Gbits/s Applications
Characteristics (continued)
Table 3. Electrical Characteristics
Parameter
Symbol
Min
Bit Rate
dc Power Supply Voltages
Power Consumption
Output Data Voltage:â
Single Output
Differential Output
Output Flag Voltage:â¡
High
Low
â
VCC
â
SV
DV
VFOH
VFOL
100
4.75
â
0.3
0.6
2.5
0
* Typical values measured at room temperature and beginning of life.
â Measured with a 50 ⦠load to ground. Outputs must be ac-coupled (see Figure 2).
â¡ TTL output.
Typ*
â
5.0
0.7
â
â
5.0
0.2
Data Sheet, Rev. 1
September 2001
Max
2488.57
5.25
1.0
0.5
1.0
VCC
0.8
Unit
Mbits/s
V
W
Vp-p
Vp-p
V
V
4
Agere Systems Inc.
|
▷ |