Electrical Characteristics (continued)
Table 4. Driver Voltage and Current Characteristics
For variations in output voltage over the temperature range, see Figure 10 and Figure 11. TA = −40 °C to +125 °C.
Parameter
Symbol
Min
Typ
Max
Unit
Output Voltages:
Low1
High1:
Differential Voltage (VOH – VOL)
Output Voltage Third State:
Difference Voltage Vdo - Vdo
Third State, IOH = –1.0 mA, VCC = 4.75 V
Output Voltages (TA = 0 °C to 85 °C):
Low1
High1:
Differential Voltage (VOH – VOL)
Input Voltages:
Low, VCC = 5.25 V:
Data Input
Enable Input
High, VCC = 4.75 V
Clamp, VCC = 4.75 V, II = –5.0 mA
Short-circuit Output Current, VCC = 5.25 V
Input Currents, VCC = 5.25 V:
Low, VI = 0.4 V
High, VI = 2.7 V
Reverse, VI = 5.25 V
VOL
VOH
VDIFF
VDIFZ
VOZ
VOL
VOH
VDIFF
VIL2
VIL3
VIL3
VIH2
VIK
IOS
IIL
IIH
IIH
VOH – 1.4
VCC − 1.8
0.65
0.4
—
VOH – 1.4
VCC − 1.5
0.8
—
—
—
2.0
—
–100
—
—
—
VOH − 1.1 VOH − 0.65
V
VCC − 1
VCC − 0.8
V
1.1
1.4
V
0.6
—
V
—
VOL − 0.2
V
VOH − 1.1
VOH − 0.8
V
VCC − 1
VCC − 0.8
V
1.1
1.4
V
—
0.8
V
—
0.8
V
—
0.7
V
—
—
V
—
−1.0
V
—
—
mA
—
−400
µA
—
20
µA
—
100
µA
1. Values are with terminations as per Figure 7.
2. The input levels and difference voltage provide zero noise immunity and should be tested only in a static, noise-free environment.
3. Test must be performed one lead at a time to prevent damage to the device.