English
Language : 

W3011 Datasheet, PDF (3/12 Pages) Agere Systems – 1 GHz Quadrature Modulator
Data Sheet
September 1999
W3011
1 GHz Quadrature Modulator
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, as shown in Table 2. Functional operation of the device is not implied at these or
any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute
maximum ratings for extended periods can adversely affect device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Ambient Operating Temperature
Storage Temperature
Lead Temperature (soldering, 10 s)
Positive Supply Voltage
Power Dissipation
ac p-p Input Voltage
Digital Voltages
Symbol
TA
Tstg
—
VCC
PD
Vp-p
—
Min
–35
–65
—
–0.3
—
–0.3
–0.3
Max
85
150
300
4.5
650
VCC
VCC
Unit
°C
°C
°C
V
mW
V
V
Handling Precautions
Although protection circuitry has been designed into this device, proper precautions should be taken to avoid
exposure to electrostatic discharge (ESD) during handling and mounting. Lucent Technologies Microelectronics
Group employs a human-body model (HBM) and a charged-device model (CDM) for ESD-susceptibility testing
and protection design evaluation. ESD voltage thresholds are dependent on the circuit parameters used to define
the model. No industry-wide standard has been adopted for CDM. However, a standard HBM (resistance =
1500 Ω, capacitance = 100 pF) is widely used and, therefore, can be used for comparison purposes. The HBM
ESD threshold presented here was obtained by using these circuit parameters:
ESD Threshold Voltage
Model
Rating
HBM
2000
CDM (corner pins)
500
CDM (noncorner pins) 500
Lucent Technologies Inc.
3