English
Language : 

L7581 Datasheet, PDF (1/16 Pages) Agere Systems – Ringing Access Switch
Data Sheet
November 1999
L7581 Ringing Access Switch
Features
s Small size/surface-mount packaging
s Monolithic IC reliability
s Low impulse noise
s Make-before-break, break-before-make operation
s Clean, bounce-free switching
s Low, matched ON-resistance
s Built-in current limiting, thermal shutdown, and
SLIC protection
s 5 V only operation, very low power consumption
s Battery monitor, all OFF state upon loss of battery
s No EMI
s Latched logic level inputs, no drive circuitry
s Only one external protector required
Applications
s Central office
s DLC
s PBX
s DAML
s HFC/FITL
Description
The L7581 Ringing Access Switch is a monolithic
solid-state device that provides the switching func-
tionality of a 2 form C switch.
The L7581 is designed to provide power ringing
access to tip and ring in central office, digital loop
carrier, private branch exchange, digitally added
main line, and hybrid fiber coax/fiber-in-the-loop ana-
log line card applications. The L7581 has three
states: the idle talk state (line break switches closed,
ringing access switches open), the power ringing
state (line break switches open, ringing access
switches closed), and an all OFF state.
The L7581 offers break-before-make or make-before-
break switching, with simple logic level input control.
Because of the solid-state construction, voltage tran-
sients generated when switching into an inductive
ringing load during ring cadence or ring trip are mini-
mized, possibly eliminating the need for external zero
cross switching circuitry. State control is via logic
level inputs, so no additional driver circuitry is
required.
The line break switch is a linear switch that has
exceptionally low ON-resistance and an excellent
ON-resistance matching characteristic. The ringing
access switch has a breakdown voltage rating
>480 V which is sufficiently high, with proper protec-
tion, to prevent breakdown in the presence of a tran-
sient fault condition (i.e., passing the transient on to
the ringing generator).
Incorporated into the L7581Axx is a diode bridge/
SCR clamping circuit, current-limiting circuitry, and a
thermal shutdown mechanism to provide protection
to the SLIC device and subsequent circuitry during
fault conditions (see Figure 1). Positive and negative
lightning is reduced by the current-limiting circuitry
and steered to ground via diodes and the integrated
SCR. Power cross is also reduced by the current-
limiting and thermal shutdown circuits.
The L7581Bxx version provides only an integrated
diode bridge along with current limiting and thermal
shutdown, as shown in Figure 2. This will cause pos-
itive faults to be directed to ground and negative
faults to battery. In either polarity, faults are reduced
by the current-limit and/or thermal shutdown mecha-
nisms.