English
Language : 

RHD5940 Datasheet, PDF (3/6 Pages) Aeroflex Circuit Technology – RadHard-by-Design RHD5940 14-Bit Analog to Digital Converter
ABSOLUTE MAXIMUM RATINGS
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
Junction Temperature
+150
°C
Supply Voltage
VCC - VEE
+6.0
V
Input Voltage
VCC +0.4
VEE -0.4
V
Lead Temperature (soldering, 10 seconds)
300
°C
Thermal Resistance, Junction to Case,jc
3.5
°C/W
ESD Rating
2.0
KV
Power @25°C
TBD
mW
NOTICE: Stresses above those listed under “Absolute Maximums Rating” may cause permanent damage to the device. These are stress rating only;
functional operation beyond the “Operation Conditions” is not recommended and extended exposure beyond the “Operation Conditions” may affect
device reliability.
Symbol
+VCC
RECOMMENDED OPERATING CONDITIONS
Power Supply Voltage
Parameter
Typical
5.0
Units
V
ELECTRICAL PERFORMANCE CHARACTERISTICS
(TC = -55°C TO +125°C, +VCC = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter
Supply Current Sleep
Supply Current Static
Supply Current Dynamic
High Analog Reference Voltage
Low Analog Reference Voltage
Symbol
ICCS
ICCQ
ICCD
PREF
NREF
Conditions
Min
Typ
1
4
VEE
Full-scale Input Range
Operating Range
Input Capacitance
Effective Number of Bits
Integral Non Linearity
Differential Non Linearity
DC Offset
DC Gain
Input Range
Reference Input Current
EOB
INL
DNL
0
-0.1
40
14
0.5
0.5
TBD
1
4
Max
TBD
TBD
TBD
VCC
PREF -
NREF
PREF -
NREF +0.1
TBD
5
TBD
Units
mA
mA
mA
V
V
V
V
pF
BITS
LSB
LSB
V
V
V
mA
SCD5940 Rev A Advanced 1/10/12
3
Aeroflex Plainview