English
Language : 

RHD5904 Datasheet, PDF (3/7 Pages) Aeroflex Circuit Technology – RadHard-by-Design RHD5904 Quad Operational Amplifier Instrumentation Amplifier with Enables
ABSOLUTE MAXIMUM RATINGS
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
Junction Temperature
+150
°C
Supply Voltage
VCC - VEE
+6.0
V
Input Voltage
VCC +0.4
VEE -0.4
V
Lead Temperature (soldering, 10 seconds)
300
°C
Thermal Resistance, Junction to Case,jc
7
°C/W
ESD Rating
2.0
KV
Power @ 25°C
200
mW
NOTICE: Stresses above those listed under “Absolute Maximums Rating” may cause permanent damage to the device. These are stress rating only;
functional operation beyond the “Operation Conditions” is not recommended and extended exposure beyond the “Operation Conditions” may affect
device reliability.
Symbol
+VCC
VCM
RECOMMENDED OPERATING CONDITIONS
Power Supply Voltage
Input Common Mode Range
Parameter
Typical
3.3 to 5.0
VCC to VEE
Units
V
V
ELECTRICAL PERFORMANCE CHARACTERISTICS
(TC = -55°C TO +125°C, +VCC = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter
Symbol
Conditions
Min
Typ
Input Offset Voltage
VOS
-2
Input Offset Current
IOS
-10
Input Bias Current
IB
-20
Input Offset TempCo 2/
VIOST
Common Mode Rejection Ratio
CMRR
70
Power Supply Rejection Ratio
PSRR
70
Output Voltage High
Output Voltage Low
Short Circuit
Output Current 2/
Slew Rate
Open Loop Gain 2/
Unity Gain Bandwidth
VOH
ROUT = 3.6 Kohms to GND
4.9
VOL
ROUT = 3.6 Kohms to VCC
IO(SINK) VOUT to VCC
-63
IO(SOURCE) VOUT to VEE
SR
RL = 8K
2.5
AOL
No Load
100
UGBW RL = 10K
5
SCD5904 Rev A Advanced 9/26/12
3
Max
Units
2
mV
10
pA
20
pA
10
uV/C
dB
dB
V
0.1
V
mA
45
mA
V/uS
dB
MHz
Aeroflex Plainview