CQFP - Flat Package Outline
POWER SUPPLY REQUIREMENTS
CURRENT
MAX UNIT
Transmitter standby (both channels) 60
25% duty cycle (one channel)
50% duty cycle (one channel)
mA
220 mA
350 mA
POWER DISSIPATION
Transmitter standby (both channels) 0.3
50% duty cycle (one channel)
100% duty cycle (one channel)
MAX
watts
0.6
0.9
UNIT
watts
watts
POWER SUPPLY DECOUPLING
To maximize stabilization of the devices transceivers, a 4.7 uf
and a 0.1 uf capacitor should be connected in parallel from the
+5V supply to ground.
APPLICATION NOTES
CIRCUIT TO TRANSFER DATA FROM SUBSYSTEM
SCDCT2578 REV B 3/11/98