English
Language : 

BEU8636-08 Datasheet, PDF (1/9 Pages) Aeroflex Circuit Technology – Balancing for 8-Cell Battery Cell Voltage Monitoring and Telemetry Reconditioning Load Control Cell Bypass Relay Drivers
Cell Management Electronics for Lithium-Ion Battery
BEU8636-08
Balancing for 8-Cell Battery
Cell Voltage Monitoring and Telemetry
Reconditioning Load Control
Cell Bypass Relay Drivers
www.aeroflex.com/BEU
March 3, 2008
Description
The Aeroflex 8636-08 is a Lithium-Ion cell
balancing system. It controls the balancing
of one battery consisting of a series stack
of Lithium-Ion cells to ensure that each cell
is precisely charged to its proper level of
energy and to monitor each cell's
operational voltage.
The cell balancing circuitry uses a set of
bilateral DC-DC converters which tie each
cell of a battery to a common share bus.
Cell charge is distributed among the
multiple cells so that the charge of each
cell is automatically matched to the
average charge of the other cells.
Features
● Cell Balancing to within ±5.0mV
● Cell Voltage Monitoring Accuracy
±10.0mV (±20.0mV Space Mission Life)
● Total Battery Voltage Monitoring
Accuracy ±0.3% of Full Scale
● Supports 8 Lithium-Ion battery cells in
series.
● Battery Drain Current at Balance
15mA maximum
● Discrete output lines for critical signaling
with user definable thresholds:
Overvoltage Protection 4.40V typ
Cell Voltage High
4.20V typ
Cell Voltage Low
3.20V typ
● MIL-STD-1553B telemetry for data
logging and monitoring
SCD8636-08 Rev A
Safety
The safety of Lithium-Ion battery
technology requires that extreme care be
taken in the provisions made for cell
charging and cell monitoring.
Precision measurements of each of the
individual cell voltages in the battery stack
and precise charge balancing to each
individual cell are critical.
The Aeroflex 8636-08 provides the
necessary precision of control and
monitoring to ensure that safety.
Discrete logic outputs are provided for
critical signaling, enabling the user to
initiate load shedding and/or to halt
charging.
Low operating losses enable continuous
operation. Continuous balancing provides
maximum protection against any one cell
becoming overcharged.