English
Language : 

D600D Datasheet, PDF (1/1 Pages) American Electronic Components, inc – Optical Liquid Level Sensors
Optical Liquid Level Sensors
D600D Series
Features: * 1/2” SAE Threaded Body
* Low cost
* Compact size
* High reliability
* Wide range of commercial and
industrial applications.
Housing Style
Output Function
Repeatability
Hysteresis
Response time rising liquid
Response time falling liquid (ethanol)
Supply Voltage (Vs)
Supply Current
Sink / Source Current
Temperature range: operating / (storage)
Housing Material
Cable Length
Environmental
Thermal Testing
Humidity
Vibration
Mechanical Shock
Max. Pressure
Order Codes:
D600
1/2” SAE-20 Thread (1)
Digital (High or Low in Air) outputs
± 1mm
1mm depending on liquid
50µS
< 1 second
5 to 12Vdc
15mA nominal
15mA
-25°C to +80°C / (–30° to +85°C)
Polysulphone UDEL 1700
200mm PTFE wires
IP67 Rated
As per BS EN60068-2-33
As per BS EN60068-2-30
As per BS EN60068 Part S3: 1996
As per BS EN60068-2-27 Part 2 Ea: 1987
7 bar
High in Air Sensors: Output Voltage in Liquid < 1Vdc; Output Voltage in Air is within Vs - 0.5Vdc
3 Wire
D600D3SH
4 Wire (2) D600D4SH
Low in Air Sensors: Output Voltage in Liquid is within Vs - 0.5VDC; Output Voltage in Air < 1Vdc
3 Wire
D600D3LSH
4 Wire (2) D600D4LSH
1)
“O” Ring supplied, unassembled.
2)
In certain applications (when used in certain liquids or emulsions and in heavily condens-
ing applications), it may be necessary to “tune” the sensor’s operation using a 4th wire
connected directly to the LED. This requires the installer to select a suitable current limiting
resistor—contact factory for details.
© American Electronic Components Inc 2008
Specifications are subject to change without notice. E&OE.
Drawing dimensions in millimetres
American Electronic Components Inc.,
1101 Lafayette Street, Elkhart, Indiana. USA
Tel: +1-574-295-6330 Fax: +1-574-293-8013
Email: sales@aecsensors.com
http://www.aecsensors.com
D600D 290808