ADAM-2632Z Datasheet, PDF (1/1 Pages) Advantech Co., Ltd. – Wireless Temperature & Humidity Sensor Node | |||
|
ADAM-2031Z
ADAM-2632Z
NEW
Wireless Temperature & Humidity
Sensor Node
Wireless Temperature & Humidity &
CO2 Sensor Node
NEW
ADAM-2031Z
RoHS
COMPLIANT
2002/95/EC
Specifications
Temperature Sensor Input
ÂÂ Operating Range
ÂÂ Resolution
ÂÂ Accuracy
-20°C ~ 70°C (-4°F ~ 157.9°F)
0.02°C (0.04°F)
±1.0°C (33.8°F)(±0.5°C @ 0 ~ +35°C)
ÂÂ Repeatability
±0.1°C (0.4°F)
ÂÂ Response Rate
ÂÂ Long Term Drift
±1°C/min.
< 0.04°C/Year (0.07°F/Year)
Humidity Sensor Input
ÂÂ Operating Range
0 ~ 100% RH
ÂÂ Resolution
0.15% RH
ÂÂ Accuracy
±3.0% RH
ÂÂ Repeatability
±0.1% RH
ÂÂ Response Time
8 seconds (Achieving 63% of a step function)
ÂÂ Long Term Drift
0.5% RH/Year
Ordering Information
ÂÂ ADAM-2031Z
Wireless Temperature & Humidity Sensor Node
ADAM-2632Z
RoHS
COMPLIANT
2002/95/EC
Specifications
Temperature Sensor Input
ÂÂ Operating Range
ÂÂ Resolution
ÂÂ Accuracy
ÂÂ Response Time
ÂÂ Long Term Drift
-10°C ~ 50°C (14°F ~ 122°F)
0.02°C (0.04°F)
±0.3°C
5 ~ 30s
< 0.04°C/yr
Humidity Sensor Input
ÂÂ Operating Range
ÂÂ Resolution
ÂÂ Accuracy
ÂÂ Repeatability
ÂÂ Response Time
ÂÂ Long Term Drift
0 ~ 100% RH
0.15% RH
±3.0% RH
±0.1% RH
8 seconds (Achieving 63% of a step function)
0.5% RH/Year
CO2 Sensor Input
ÂÂ Resolution
12 Bit (CC2530 ADC, ENOB)
 Conversion / Response Time 132μs (CC2530 ADC) / 1.5 ~ 2.5 min
ÂÂ Operating Range
350 ~ 10,000ppm of CO2
ÂÂ Operating Cond.
-10°C ~ +50°C, 5 ~ 95%RH
Ordering Information
ÂÂ ADAM-2632Z
Wireless Temperature & Humidity & CO2 Sensor Node
Common Specifications
Wireless Communication
ÂÂ IEEE Standard
ÂÂ Modulation Type
ÂÂ Frequency Band
ÂÂ Channels
ÂÂ RF Data Rate
ÂÂ Transmit Power
ÂÂ Receiver Sensitivity
ÂÂ Topology
ÂÂ Outdoor Range
ÂÂ Function
IEEE 802.15.4
DSSS (OQPSK)
ISM 2.4 GHz (2.4 GHz ~ 2.4835 GHz)
11 - 26
250 Kbps
ADAM-2031Z: Typ. 3 ± 1 dBm
ADAM-2632Z: Typ. 19 ± 1 dBm
-97 dBm
Star / Tree / Mesh
ADAM-2031Z: 110 m
ADAM-2632Z: 1000 m
End Device
M2M I/O Modules
General
ÂÂ Connectors
ÂÂ Power Input
ÂÂ Battery Input
ÂÂ Power Consumption
Environment
1 x plug-in terminal block (#14 ~ 22 AWG)
Unregulated 10 ~ 30 VDC
2 x AA Alkaline
0.3 W @ 24 VDC
Battery AA * 2
420 uW @ 3 VDC (1 minute Tx Interval)
240 uW @ 3 VDC (2 minute Tx Interval)
150 uW @ 3 VDC (5 minute Tx Interval)
ÂÂ Operating Temperature
External Power
ADAM-2031Z : -20°C ~ 70°C (-4°F ~ 157.9°F)
ADAM-2632Z : -10°C ~ 50°C (14°F ~ 122°F)
Battery Power
0°C ~ 50°C (32°F ~ 122°F)
 Storage Temperature -40°C~ 85°C (-40°F ~ 184°F )
ÂÂ Operating Humidity 20~95% RH
ÂÂ Storage Humidity
0~95% RH
|