English
Language : 

SD100-41-21-231 Datasheet, PDF (1/2 Pages) Advanced Photonix, Inc. – Detector/Amplifier Hybrids Without Feedback Resistor RED ENHANCED
Detector/Amplifier Hybrids Without Feedback Resistor
RED ENHANCED
SD 100-41-21-231
PACKAGE DIMENSIONS INCH
3
2
4
1
5
876
CHIP DIMENSIONS
TO-5 PACKAGE
FEATURES
• Low noise
• Red enhanced
• Custom feedback
• High speed
DESCRIPTION
The SD 100-42-21-231 is a red enhanced
detector/amplifier that combines a silicon photodiode
with an opamp without a feedback network,
Packaged in a hermetic TO-5 metal can package.
APPLICATIONS
• Instrumentation
• Industrial
• Medical
AMPLIFIER SPECIFICATIONS (TA)= 23°C UNLESS OTHERWISE NOTED
SYMBOL PARAMETER
MIN TYP MAX UNITS
Vs
Voltage Supplies
Vio Input Offset Voltage
Vn
Input Voltage Noise
@ f = 10KHz
Iib
Input Bias Current
In
Input Current Noise
@ f = 10KHz
± 5 ± 15 ± 18 V
1
2
mV
12
nV/√Hz
15
40
pA
20
30 fA/√Hz
DETECTOR SPECTRAL RESPONSE
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
GBP
IS
Gain Bandwidth Product
Supply Current
18
6.5 7
MHz
mA
Wavelength (nm)
TSTG
TO
Storage Temperature -65
Operating Temperature -40
+125 °C
+85 °C
DETECTOR SPECIFICATIONS (TA)= 23°C UNLESS OTHERWISE NOTED
SYMBOL
ID
RSH
CJ
lrange
R
CHARACTERISTIC
Dark Current
Shunt Resistance
Junction Capacitance
Spectral Application Range
Responsivity
TEST CONDITIONS
VR = 10 V
VR = 0 V
VR = 0 V, f = 1 MHz
VR = 10 V, f = 1 MHz
Spot Scan
l= 950 nm, VR = 0 V
MIN
TYP MAX UNITS
10
nA
300
MW
87
18
pF
250
1100 nm
0.64
A/W