English
Language : 

APT40GP60B2DF2 Datasheet, PDF (7/9 Pages) Advanced Power Technology – POWER MOS 7 IGBT
TYPICAL PERFORMANCE CURVES
APT40GP60B2DF2
ULTRAFAST SOFT RECOVERY ANTI-PARALLEL DIODE
MAXIMUM RATINGS
All Ratings: TC = 25°C unless otherwise specified.
Symbol Characteristic / Test Conditions
APT40GP60B2DF2
UNIT
IF(AV)
IF(RMS)
IFSM
Maximum Average Forward Current (TC = 99°C, Duty Cycle = 0.5)
RMS Forward Current (Square wave, 50% duty)
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
30
49
Amps
320
STATIC ELECTRICAL CHARACTERISTICS
Symbol Characteristic / Test Conditions
MIN TYP MAX UNIT
VF
Forward Voltage
IF = 40A
IF = 80A
IF = 40A, TJ = 125°C
2.4
3.0
Volts
1.8
DYNAMIC CHARACTERISTICS
Symbol Characteristic
Test Conditions
MIN TYP MAX UNIT
trr
Reverse Recovery Time IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C
-
21
ns
trr
Reverse Recovery Time
-
62
Qrr
Reverse Recovery Charge
IF = 30A, diF/dt = -200A/µs
VR = 400V, TC = 25°C
-
65
nC
IRRM Maximum Reverse Recovery Current
-
3
-
Amps
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM Maximum Reverse Recovery Current
IF = 30A, diF/dt = -200A/µs
VR = 400V, TC = 125°C
-
113
ns
-
411
nC
-
7
-
Amps
trr
Reverse Recovery Time
-
49
Qrr
Reverse Recovery Charge
IF = 30A, diF/dt = -1000A/µs
VR = 400V, TC = 125°C
-
704
IRRM Maximum Reverse Recovery Current
-
22
ns
nC
Amps
APT Reserves the right to change, without notice, the specifications and information contained herein.
0.70
0.60
0.9
0.50
0.7
0.40
0.5
0.30
Note:
0.20
0.10
0
10-5
0.3
t1
0.1
SINGLE PULSE
0.05
t2
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (seconds)
FIGURE 25a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
RC MODEL
Junction
temp (°C)
Power
(watts)
0.378 °C/W
0.00232 J/°C
0.291 °C/W
0.110 J/°C
Case temperature (°C)
FIGURE 25b, TRANSIENT THERMAL IMPEDANCE MODEL