English
Language : 

APT4020BN Datasheet, PDF (2/4 Pages) Advanced Power Technology – N-CHANNEL ENHANCEMENT MODE HIGH VOLTAGE POWER MOSFETS
DYNAMIC CHARACTERISTICS
Symbol
Ciss
Coss
Crss
Qg
Qgs
Qgd
td(on)
tr
td(off)
tf
Characteristic
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge 3
Gate-Source Charge
Gate-Drain ("Miller ") Charge
Turn-on Delay Time
Rise Time
Turn-off Delay Time
Fall Time
Test Conditions
VGS = 0V
VDS = 25V
f = 1 MHz
VGS = 10V
VDD = 0.5 VDSS
ID = ID [Cont.] @ 25°C
VGS = 15V
VDD = 0.5 VDSS
ID = ID [Cont.] @ 25°C
RG = 1.8Ω
APT4020/4025BN
MIN TYP MAX UNIT
2380 2950
563 750 pF
207 310
94 130
11
16
nC
47
70
14
28
29
57
ns
60
90
40
80
SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS
Symbol Characteristic / Test Conditions / Part Number
IS
Continuous Source Current
(Body Diode)
APT4020BN
APT4025BN
ISM
Pulsed Source Current 1
(Body Diode)
APT4020BN
APT4025BN
VSD Diode Forward Voltage 2 (VGS = 0V, IS = -ID [Cont.])
t rr
Reverse Recovery Time (IS = -ID [Cont.], dlS/dt = 100A/µs)
Q rr Reverse Recovery Charge (IS = -ID [Cont.], dlS/dt = 100A/µs)
MIN TYP MAX UNIT
26
23
Amps
104
92
1.3 Volts
360 720 ns
6
12
µC
SAFE OPERATING AREA CHARACTERISTICS
Symbol Characteristic
Test Conditions / Part Number
MIN
SOA1
SOA2
ILM
Safe Operating Area
VDS = 0.4 VDSS, IDS = PD / 0.4 VDSS, t = 1 Sec. 310
Safe Operating Area
IDS = ID [Cont.], VDS = PD / ID [Cont.], t = 1 Sec. 310
Inductive Current Clamped
APT4020BN
104
APT4025BN
92
TYP
MAX
1 Repetitive Rating: Pulse width limited by maximum junction temperature. See Transient Thermal Impedance Curve. (Fig.1)
2 Pulse Test: Pulse width < 380 µS, Duty Cycle < 2%
3 See MIL-STD-750 Method 3471
APT Reserves the right to change, without notice, the specifications and information contained herein.
1.0
0.5
D=0.5
0.1
0.2
0.05
0.1
0.05
0.02
0.01
0.01
Note:
t1
0.005
SINGLE PULSE
t2
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
0.001
10-5
10-4
10-3
10-2
10-1
1.0
10
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION
UNIT
Watts
Amps