English
Language : 

APT30M30JLL_04 Datasheet, PDF (2/5 Pages) Advanced Power Technology – POWER MOS 7 R MOSFET
DYNAMIC CHARACTERISTICS
APT30M30JLL
Symbol
Ciss
Coss
Crss
Qg
Qgs
Qgd
td(on)
tr
td(off)
tf
Eon
Eoff
Eon
Eoff
Characteristic
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge 3
Gate-Source Charge
Gate-Drain ("Miller") Charge
Turn-on Delay Time
Rise Time
Turn-off Delay Time
Fall Time
Turn-on Switching Energy 6
Turn-off Switching Energy
Turn-on Switching Energy 6
Turn-off Switching Energy
Test Conditions
VGS = 0V
VDS = 25V
f = 1 MHz
VGS = 10V
VDD = 150V
ID = 88A @ 25°C
RESISTIVE SWITCHING
VGS = 15V
VDD = 150V
ID = 88A @ 25°C
RG = 0.6Ω
INDUCTIVE SWITCHING @ 25°C
VDD = 200V, VGS = 15V
ID = 88A, RG = 5Ω
INDUCTIVE SWITCHING @ 125°C
VDD = 200V, VGS = 15V
ID = 88A, RG = 5Ω
MIN
TYP
7030
1895
110
140
41
70
15
19
35
9
815
1185
850
1250
MAX
UNIT
pF
nC
ns
µJ
SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS
Symbol Characteristic / Test Conditions
MIN TYP MAX UNIT
IS
Continuous Source Current (Body Diode)
ISM
Pulsed Source Current 1 (Body Diode)
VSD Diode Forward Voltage 2 (VGS = 0V, IS = -88A)
t rr
Reverse Recovery Time (IS = -88A, dlS/dt = 100A/µs)
Q rr Reverse Recovery Charge (IS = -88A, dlS/dt = 100A/µs)
dv/dt Peak Diode Recovery dv/dt 5
450
10.0
88
Amps
352
1.3 Volts
ns
µC
5
V/ns
THERMAL CHARACTERISTICS
Symbol Characteristic
MIN TYP MAX UNIT
RθJC
RθJA
Junction to Case
Junction to Ambient
0.24
°C/W
40
1 Repetitive Rating: Pulse width limited by maximum junction
temperature
2 Pulse Test: Pulse width < 380 µs, Duty Cycle < 2%
3 See MIL-STD-750 Method 3471
4 Starting Tj = +25°C, L = 0.77mH, RG = 25Ω, Peak IL = 88A
5 dv/dt numbers reflect the limitations of the test circuit rather than the
device itself. IS ≤ -ID88A di/dt ≤ 700A/µs VR ≤ 300V TJ ≤ 150°C
6 Eon includes diode reverse recovery. See figures 18, 20.
APT Reserves the right to change, without notice, the specifications and inforation contained herein.
0.25
0.9
0.20
0.7
0.15
0.10
0.05
0
10-5
0.5
Note:
0.3
0.1
0.05
SINGLE PULSE
t1
t2
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION