English
Language : 

APT30GT60BR Datasheet, PDF (2/6 Pages) Advanced Power Technology – The Thunderbolt IGBT™ is a new generation of high voltage power IGBTs.
DYNAMIC CHARACTERISTICS
Symbol
Cies
Coes
Cres
VGEP
Qg
Qge
Qgc
Characteristic
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Gate-to-Emitter Plateau Voltage
Total Gate Charge 3
Gate-Emitter Charge
Gate-Collector ("Miller ") Charge
SSOA Switching Safe Operating Area
td(on)
tr
td(off)
tf
Eon1
Eon2
Eoff
td(on)
tr
td(off)
tf
Eon1
Eon2
Eoff
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4
Turn-on Switching Energy (Diode) 5
Turn-off Switching Energy 6
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4 4
Turn-on Switching Energy (Diode) 55
Turn-off Switching Energy 6
APT30GT60BR(G)
Test Conditions
MIN TYP MAX
Capacitance
1600
VGE = 0V, VCE = 25V
150
f = 1 MHz
92
Gate Charge
7.5
VGE = 15V
VCE = 300V
IC = 30A
145
10
60
TJ = 150°C, RG = 10Ω, VGE =
15V, L = 100µH,VCE = 600V 1 10
Inductive Switching (25°C)
12
VCC = 400V
VGE = 15V
IC = 30A
RG = 10Ω
TJ = +25°C
20
225
80
525
605
600
Inductive Switching (125°C)
12
VCC = 400V
VGE = 15V
IC = 30A
RG = 10Ω
TJ = +125°C
20
245
100
570
965
830
UNIT
pF
V
nC
A
ns
µJ
ns
µJ
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol
RθJC
RθJC
WT
Characteristic
Junction to Case (IGBT)
Junction to Case (DIODE)
Package Weight
MIN TYP
5.9
MAX
.50
N/A
UNIT
°C/W
gm
1 Repetitive Rating: Pulse width limited by maximum junction temperature.
2 For Combi devices, Ices includes both IGBT and FRED leakages
3 See MIL-STD-750 Method 3471.
4 Eon1 is the clamped inductive turn-on energy of the IGBT only, without the effect of a commutating diode reverse recovery current
adding to the IGBT turn-on loss. Tested in inductive switching test circuit shown in figure 21, but with a Silicon Carbide diode.
5 Eon2 is the clamped inductive turn-on energy that includes a commutating diode reverse recovery current in the IGBT turn-on switching
loss. (See Figures 21, 22.)
6 Eoff is the clamped inductive turn-off energy measured in accordance with JEDEC standard JESD24-1. (See Figures 21, 23.)
APT Reserves the right to change, without notice, the specifications and information contained herein.