DYNAMIC CHARACTERISTICS
Symbol
Ciss
Coss
Crss
Qg
Qgs
Qgd
td(on)
tr
td(off)
tf
Characteristic
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge 3
Gate-Source Charge
Gate-Drain ("Miller") Charge
Turn-on Delay Time
Rise Time
Turn-off Delay Time
Fall Time
Test Conditions
VGS = 0V
VDS = 25V
f = 1 MHz
VGS = 10V
VDD = 150V
ID = 100A @ 25°C
VGS = 15V
VDD = 150V
ID = 100A @ 25°C
RG = 0.6Ω
SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS
Symbol Characteristic / Test Conditions
IS
Continuous Source Current (Body Diode)
ISM Pulsed Source Current 1 (Body Diode)
VSD Diode Forward Voltage 2 (VGS = 0V, IS = -100A)
dv/dt Peak Diode Recovery dv/dt 5
Reverse Recovery Time
trr
(IS = -100A, di/dt = 100A/µs)
Tj = 25°C
Tj = 125°C
Reverse Recovery Charge
Qrr
(IS = -100A, di/dt = 100A/µs)
Tj = 25°C
Tj = 125°C
IRRM
Peak Recovery Current
(IS = -100A, di/dt = 100A/µs)
Tj = 25°C
Tj = 125°C
APT20M18B2VFR_LVFR
MIN TYP MAX UNIT
9880
2320
pF
700
330
55
nC
145
18
27
ns
55
6
MIN TYP MAX UNIT
100 Amps
400
1.3 Volts
8
V/ns
230
ns
450
0.9
µC
3.4
11
Amps
20
THERMAL CHARACTERISTICS
Symbol Characteristic
RθJC
RθJA
Junction to Case
Junction to Ambient
MIN TYP MAX UNIT
0.20
40
°C/W
1 Repetitive Rating: Pulse width limited by maximum junction
temperature
2 Pulse Test: Pulse width < 380 µs, Duty Cycle < 2%
3 See MIL-STD-750 Method 3471
4 Starting Tj = +25°C, L = 600µH, RG = 25Ω, Peak IL = 100A
5 dv/dt numbers reflect the limitations of the test circuit rather than the
device itself. IS ≤ -ID100A di/dt ≤ 200A/µs VR ≤200V TJ ≤ 150°C
6 The maximum current is limited by lead temperature.
APT Reserves the right to change, without notice, the specifications and information contained herein.
0.25
0.20
0.9
0.15
0.7
0.10
0.05
0
10-5
Note:
0.5
t1
0.3
0.1
0.05
SINGLE PULSE
t2
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION