APT2X61D40J_05 Datasheet, PDF (1/4 Pages) Advanced Power Technology – ULTRAFAST SOFT RECOVERY RECTIFIER DIODE | |||
|
2
3
2
3
2
3
1
4
Anti-Parallel
APT2X60D40J
1
4
Parallel
APT2X61D40J
1
4
ISOTOP®
"UL Recognized"
APT2X61D40J
APT2X60D40J
®
400V 60A
400V 60A
DUAL DIE ISOTOP® PACKAGE
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
PRODUCT APPLICATIONS
⢠Anti-Parallel Diode
-Switchmode Power Supply
-Inverters
⢠Free Wheeling Diode
-Motor Controllers
-Converters
⢠Snubber Diode
⢠Uninterruptible Power Supply (UPS)
⢠Induction Heating
⢠High Speed Rectiï¬ers
PRODUCT FEATURES
⢠Ultrafast Recovery Times
⢠Soft Recovery Characteristics
⢠Popular SOT-227 Package
⢠Low Forward Voltage
⢠High Blocking Voltage
⢠Low Leakage Current
PRODUCT BENEFITS
⢠Low Losses
⢠Low Noise Switching
⢠Cooler Operation
⢠Higher Reliability Systems
⢠Increased System Power
Density
MAXIMUM RATINGS
Symbol Characteristic / Test Conditions
All Ratings: TC = 25°C unless otherwise speciï¬ed.
APT2X61_60D40J
UNIT
VR
VRRM
VRWM
IF(AV)
IF(RMS)
IFSM
TJ,TSTG
TL
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (TC = 115°C, Duty Cycle = 0.5)
RMS Forward Current (Square wave, 50% duty)
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Operating and StorageTemperature Range
Lead Temperature for 10 Sec.
400
60
99
600
-55 to 175
300
Volts
Amps
°C
STATIC ELECTRICAL CHARACTERISTICS
Symbol Characteristic / Test Conditions
VF
Forward Voltage
IRM Maximum Reverse Leakage Current
CT
Junction Capacitance, VR = 200V
IF = 60A
IF = 120A
IF = 60A, TJ = 125°C
VR = VR Rated
VR = VR Rated, TJ = 125°C
MIN TYP MAX UNIT
1.3 1.5
1.6
Volts
1.2
250
µA
500
120
pF
APT Website - http://www.advancedpower.com
|
▷ |