English
Language : 

APT10090BLL_03 Datasheet, PDF (1/5 Pages) Advanced Power Technology – Power MOS 7TM is a new generation of low loss, high voltage, N-Channel enhancement mode power MOSFETS.
APT10090BLL
APT10090SLL
1000V 12A 0.900Ω
POWER MOS 7 R MOSFET
BLL
Power MOS 7® is a new generation of low loss, high voltage, N-Channel
enhancement mode power MOSFETS. Both conduction and switching
losses are addressed
and Qg. Power MOS
with Power MOS 7® by significantly lowering
7® combines lower conduction and switching
RDS(ON)
losses
along with exceptionally fast switching speeds inherent with APT's
patented metal gate structure.
• Lower Input Capacitance • Increased Power Dissipation
TO-247
D3PAK
SLL
D
• Lower Miller Capacitance • Easier To Drive
• Lower Gate Charge, Qg
• TO-247 or Surface Mount D3PAK Package
G
S
MAXIMUM RATINGS
All Ratings: TC = 25°C unless otherwise specified.
Symbol
VDSS
ID
IDM
VGS
VGSM
PD
TJ,TSTG
TL
IAR
EAR
EAS
Parameter
Drain-Source Voltage
Continuous Drain Current @ TC = 25°C
Pulsed Drain Current 1
Gate-Source Voltage Continuous
Gate-Source Voltage Transient
Total Power Dissipation @ TC = 25°C
Linear Derating Factor
Operating and Storage Junction Temperature Range
Lead Temperature: 0.063" from Case for 10 Sec.
Avalanche Current 1 (Repetitive and Non-Repetitive)
Repetitive Avalanche Energy 1
Single Pulse Avalanche Energy 4
APT10090
1000
12
48
±30
±40
298
2.4
-55 to 150
300
12
30
1210
UNIT
Volts
Amps
Volts
Watts
W/°C
°C
Amps
mJ
STATIC ELECTRICAL CHARACTERISTICS
Symbol Characteristic / Test Conditions
MIN TYP MAX
BVDSS
ID(on)
RDS(on)
IDSS
IGSS
VGS(th)
Drain-Source Breakdown Voltage (VGS = 0V, ID = 250µA)
On State Drain Current 2 (VDS > ID(on) x RDS(on) Max, VGS = 10V)
Drain-Source On-State Resistance 2 (VGS = 10V, 6A)
Zero Gate Voltage Drain Current (VDS = 1000V, VGS = 0V)
Zero Gate Voltage Drain Current (VDS = 800V, VGS = 0V, TC = 125°C)
Gate-Source Leakage Current (VGS = ±30V, VDS = 0V)
Gate Threshold Voltage (VDS = VGS, ID = 1mA)
1000
12
3
0.90
100
500
±100
5
CAUTION: These Devices are Sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed.
APT Website - http://www.advancedpower.com
UNIT
Volts
Amps
Ohms
µA
nA
Volts