Register Access
Clicking Register Access in the menu bar of the main window
provides read/write access to all user-accessible registers in the
IMU. For example, Figure 13 demonstrates using this menu to
write 0x0009 to the DEC_RATE register in the ADIS16488 or
ADIS16375, which lowers the output data rate from 2.46 kSPS
to 246 SPS.
Evaluation Board User Guide
In this case,
1. Select Control from the Select a Category drop-down box
to access the control register group.
2. Click DEC_RATE in the register listing.
3. Type 9 in the New Hex Value box.
4. Click Write Register to write this value to the register
inside the IMU.
5. Click Update Flash to make this setting nonvolatile.
Figure 13. Register Access, Write DEC_RATE = 0x0009 Example
Rev. B | Page 8 of 12