When these steps are completed, the voltage source can be
turned on. If J1 is inserted (connecting EN to VIN for auto-
matic startup), the regulator powers up.
GROUND CURRENT CONSUMPTION
Ground current measurements can determine how much current
the internal circuits of the regulator consume while the circuits
perform the regulation function. To be efficient, the regulator
must consume as little current as possible. Typically, the regulator
uses the maximum current when supplying its largest load level
(150 mA). Figure 12 shows the typical ground current consump-
tion for various load levels at VOUT = 3.3 V and TA = 25°C.
When the device is disabled (EN = GND), ground current
drops to less than 1 μA.
UG-054
250
IOUT = 150mA
200
IOUT = 100mA
150
IOUT = 50mA
100
IOUT = 10mA
50
IOUT = 1mA
IOUT = 0.1mA
0
3.5 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.5
VIN (V)
Figure 12. Ground Current vs. Input Voltage (VIN) at VOUT = 3.3 V, TA = 25°C
Rev. 0 | Page 7 of 8