English
Language : 

OP297 Datasheet, PDF (7/16 Pages) Analog Devices – Dual Low Bias Current Precision Operational Amplifier
8/21/97 4:00 PM
100
80
GAIN
60
PHASE
40
20
VS = ±15V
CL = 30pF
RL = 1MΩ
TA = –55°C 90
135
0
180
–20
–40
100
225
TA = +125°C
1k 10k 100
1M 10M
FREQUENCY (Hz)
Figure 22. Open Loop Gain,
Phase vs. Frequency
70
TA = +25°C
60 VS = ±15V
AVCL = +1
50 VOUT = 100mVp-p
40
–EDGE
+EDGE
30
20
10
0
10
100
1000
10000
LOAD CAPACITANCE (pF)
Figure 23. Small Signal Overshoot
vs. Capacitance Load
OP297
1000
100
TA = +25°C
VS = ±15V
10
1
0.1
0.01
0.001
10
100
1k
10k 100k 1M
FREQUENCY (Hz)
Figure 24. Open Loop Output
Impedance vs Frequency
APPLICATIONS INFORMATION
Extremely low bias current over the full military temperature
range makes the OP297 attractive for use in sample-and-hold
amplifiers, peak detectors, and log amplifiers that must operate
over a wide temperature range. Balancing input resistances is
not necessary with the OP297 Offset voltage and TCVOS are
degraded only minimally by high source resistance, even when
unbalanced.
The input pins of the OP297 are protected against large differ-
ential voltage by back-to-back diodes and current-limiting resis-
tors. Common-mode voltages at the inputs are not restricted,
and may vary over the full range of the supply voltages used.
The OP297 requires very little operating headroom about the
supply rails, and is specified for operation with supplies as low
as +2 V. Typically, the common-mode range extends to within
one volt of either rail. The output typically swings to within one
volt of the rails when using a 10 kΩ load.
AC PERFORMANCE
The OP297’S AC characteristics are highly stable over its full
operating temperature range. Unity-gain small-signal response is
shown in Figure 25. Extremely tolerant of capacitive loading on
the output, the OP297 displays excellent response even with
1000 pF loads (Figure 26).
100
90
10
0%
20mV
5µs
100
90
10
0%
20mV
5µs
Figure 26. Small-Signal Transient Response
(CLOAD = 1000 pF, AVCL = +1)
100
90
10
0%
20mV
5µs
Figure 27. Large-Signal Transient Response
(AVCL = +1)
GUARDING AND SHIELDING
To maintain the extremely high input impedances of the
OP297, care must be taken in circuit board layout and manu-
facturing. Board surfaces must be kept scrupulously clean and
free of moisture. Conformal coating is recommended to provide
Figure 25. Small-Signal Transient Response
(CLOAD = 100 pF, AVCL = +1)
REV. D
–7–