English
Language : 

ADCMP341_15 Datasheet, PDF (7/12 Pages) Analog Devices – Comparators and Reference with Programmable Hysteresis
Data Sheet
1000
TA = –40°C
100
VDD = 5.0V
VDD = 3.3V
VDD = 2.5V
VDD = 1.7V
10
1
0.001
0.01
0.1
1
10
100
OUTPUT SINK CURRENT (mA)
Figure 12. Supply Current vs. Output Sink Current
1000
TA = 85°C
100
VDD = 5.0V
VDD = 3.3V
VDD = 2.5V
VDD = 1.7V
10
1
0.001
0.01
0.1
1
10
100
OUTPUT SINK CURRENT (mA)
Figure 13. Supply Current vs. Output Sink Current
3
1
TA = +125°C
–1
TA = +85°C
TA = +25°C
TA = –40°C
–3
–5 CURRENT IS POSITIVE
GOING INTO THE DEVICE.
VDD = 5V
0V < VIB < 1V
–7
0
0.2
0.4
0.6
0.8
1.0
INPUT VOLTAGE (V)
Figure 14. Low Level Input Bias Current
1000
TA = 25°C
100
ADCMP341/ADCMP343
VDD = 5.0V
VDD = 3.3V
VDD = 2.5V
VDD = 1.7V
10
1
0.001
0.01
0.1
1
10
100
OUTPUT SINK CURRENT (mA)
Figure 15. Supply Current vs. Output Sink Current
10k
TA = +125°C
1k
CURRENT IS GOING
OUT OF THE DEVICE.
VDD = 5V
–0.3V < VIB < 0V
100
TA = +25°C
10
TA = +85°C
1
TA = –40°C
0.1
–0.3
–0.2
–0.1
0
INPUT VOLTAGE (V)
Figure 16. Below Ground Input Bias Current
10
TA = +125°C
1
TA = +85°C
0.1
TA = +25°C
TA = –40°C
CURRENT IS GOING INTO THE DEVICE
VDD = 5V
VIB > 1V
0.01
1
2
3
4
5
INPUT VOLTAGE (V)
Figure 17. High Level Input Bias Current
Rev. A | Page 7 of 12