Data Sheet
AD9516-4
Reg.
Addr.
(Hex) Bits
0x0F1 4
Name
OUT1 invert
[3:2] OUT1 LVPECL
differential voltage
[1:0] OUT1 power-down
0x0F2 4
OUT2 invert
[3:2] OUT2 LVPECL
differential voltage
[1:0] OUT2 power-down
0x0F3 4
OUT3 invert
[3:2] OUT3 LVPECL
differential voltage
[1:0] OUT3 power-down
Description
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3 2 VOD (mV)
0 0 400
0 1 600
1 0 780 (default)
1 1 960
LVPECL power-down modes.
1 0 Mode
0 0 Normal operation.
0 1 Partial power-down, reference on; use only if there are no external load
resistors.
1 0 Partial power-down, reference on, safe LVPECL power-down (default).
1 1 Total power-down, reference off; use only if there are no external load
resistors.
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3 2 VOD (mV)
0 0 400
0 1 600
1 0 780 (default)
1 1 960
LVPECL power-down modes.
1 0 Mode
0 0 Normal operation (default).
0 1 Partial power-down, reference on; use only if there are no external load
resistors.
1 0 Partial power-down, reference on, safe LVPECL power-down.
1 1 Total power-down, reference off; use only if there are no external load
resistors.
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3 2 VOD (mV)
0 0 400
0 1 600
1 0 780 (default)
1 1 960
LVPECL power-down modes.
1 0 Mode
0 0 Normal operation.
0 1 Partial power-down, reference on; use only if there are no external
load resistors.
1 0 Partial power-down, reference on, safe LVPECL power-down (default).
1 1 Total power-down, reference off; use only if there are no external
load resistors.
Rev. C | Page 69 of 80
Output
On
Off
Off
Off
Output
On
Off
Off
Off
Output
On
Off
Off
Off