ADIS16100
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Acceleration (Any Axis, Unpowered, 0.5 ms)
Acceleration (Any Axis, Powered, 0.5 ms)
VCC to COM
VDRIVE to COM
Analog Input Voltage to COM
Digital Input Voltage to COM
Digital Output Voltage to COM
ST1/ST2 Input Voltage to COM
Operating Temperature Range
Storage Temperature Range
Rating
2000 g
2000 g
−0.3 V to +6.0 V
−0.3 V to VCC + 0.3 V
−0.3 V to VCC + 0.3 V
−0.3 V to +7.0 V
−0.3 V to VCC + 0.3 V
−0.3 V to VCC + 0.3 V
−40°C to +85°C
−65°C to +150°C
Stresses above those listed under the Absolute Maximum
Ratings may cause permanent damage to the device. This is a
stress rating only; functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Drops onto hard surfaces can cause shocks of greater than 2000 g
and exceed the absolute maximum rating of the device. Care
should be exercised in handling to avoid damage.