English
Language : 

UG-383 Datasheet, PDF (5/16 Pages) Analog Devices – Self-contained board, including synthesizer
EV-ADF4159EB1Z/EV-ADF4159EB3Z User Guide
UG-383
VCO CONFIGURATION
EV-ADF4159EB1Z
The EV-ADF4159EB1Z evaluation board has a MACOM VCO
(MAOC-009269) with a range of 11.4 GHz to 12.8 GHz installed.
The RFOUT signal is connected to the EXT_VCOOUT SMA.
The RFOUT/2 signal of the VCO is fed back to the ADF4159
PLL; therefore, when the VCO outputs 12 GHz, the ADF4159 is
locked at 6 GHz.
For optimum performance, ensure that the components values
are as described in Table 2.
Table 2. Component Values for EV-ADF4159EB1Z
Component
Value1
R73
0Ω
C29
100 pF
R31, R34, R51, R62, R68, R70, DNP
R71, R72 (Bottom Layer)
C40, C62, C63, C64, C65, C66, DNP
C70, C71, C75, C76
L3, L4
DNP
1 DNP is do not populate.
Terminate the VCO/2 SMA with 50 Ω..
EV-ADF4159EB3Z
The EV-ADF4159EB3Z evaluation board does not have a VCO
installed. The board is configured for use with an external VCO
board. Connect an external VCO to the evaluation board using
SMA cables. There are two configuration options:
• The VCO control voltage can be connected to the VTUNE
SMA, and the VCO RFOUT signal can be connected to the
VCO/2 SMA. This configuration uses the on-board loop filter.
• The CPOUT SMA can be used to connect the ADF4159
charge pump output to an external loop filter. Connect the
VCO RFOUT signal to the VCO/2 SMA to feed the signal
back into the ADF4159.
For optimum performance, ensure that the component values
are as shown in Table 3.
Table 3. Component Values for EV-ADF4159EB3Z
Component
Value1
R34
50 Ω
R31
DNP
C29
DNP
1 DNP is do not populate.