English
Language : 

OP200 Datasheet, PDF (5/12 Pages) Analog Devices – Dual Low Offset, Low Power Operational Amplifier
OP200
50⍀
1/2
OP200
50k⍀
1/2
OP200
V1 20Vp-p @ 10Hz
V2
CHANNEL SEPARATION = 20 LOG
V1
V2/1000
Figure 2. Channel Separation Test Circuit
100⍀
10k⍀
1/2
OP200
1/2
OP200
eOUT
TO SPECTRUM
ANALYZER
eOUT(nV/ Hz) = 2 ؋ eOUT(nV/ Hz) ؋ 101
Figure 3. Noise Test Schematic
ABSOLUTE MAXIMUM RATINGS1
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 V
Differential Input Voltage . . . . . . . . . . . . . . . . . . . . . . ± 30 V
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . Supply Voltage
Output Short-Circuit Duration . . . . . . . . . . . . . . Continuous
Storage Temperature Range
P, S, Z-Package . . . . . . . . . . . . . . . . . . . . . –65∞C to +150∞C
Lead Temperature Range (Soldering, 60 sec) . . . . . . . 300∞C
Junction Temperature (TJ) . . . . . . . . . . . . . –65∞C to +150∞C
Operating Temperature Range
OP200A . . . . . . . . . . . . . . . . . . . . . . . . . . . –55∞C to +125∞C
OP200E, OP200F . . . . . . . . . . . . . . . . . . . . –40∞C to +85∞C
OP200G . . . . . . . . . . . . . . . . . . . . . . . . . . . –40∞C to +85∞C
Package Type
␪JA2
␪JC
Unit
8-Pin Hermetic DIP (Z)
148
16
∞C/W
8-Pin Plastic DIP (P)
96
37
∞C/W
16-Pin SOL (S)
92
27
∞C/W
NOTES
1Absolute maximum ratings apply to both DICE and packaged parts, unless
otherwise noted.
2␪JA is specified for worst case mounting conditions, i.e., ␪JA is specified for
device in socket for CERDIP and P-DIP packages; ␪JA is specified for device
soldered to printed circuit board for SOL package.
ORDERING GUIDE
Package
TA = 25؇C
VOS Max
(␮V)
CERDIP
8-Pin
Plastic
Operating
Temperature
Range
75
OP200AZ
MIL
75
OP200EZ
XIND
150
OP200FZ*
XIND
200
OP200GP XIND
200
OP200GS XIND
*Not for new design, obsolete April 2002.
For military processed devices, please refer to the Standard
Microcircuit Drawing (SMD) available at
www.dscc.dla.mil/programs/milspec/default.asp
SMD Part Number
5962-8859301M2A
5962-8859301MPA
ADI Equivalent
OP200ARCMDA
OP200AZMDA
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the OP200 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. A
–5–