English
Language : 

ADA4000-1_07 Datasheet, PDF (5/16 Pages) Analog Devices – Low Cost, Precision JFET Input Operational Amplifiers
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Supply Voltage
Input Voltage
Differential Input Voltage
Output Short-Circuit Duration to GND
Storage Temperature Range
Operating Temperature Range
Junction Temperature Range
Lead Temperature (Soldering, 10 sec)
Rating
±18 V
±V supply
±V supply
Indefinite
−65°C to +150°C
−40°C to +125°C
−65°C to +150°C
300°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ADA4000-1/ADA4000-2/ADA4000-4
THERMAL RESISTANCE
θJA is specified for the worst-case conditions, that is, a device
soldered in a circuit board for surface-mount packages.
Table 4. Thermal Resistance
Package Type
5-Lead TSOT (UJ-5)
8-Lead SOIC (R-8)
8-Lead MSOP (RM-8)
14-Lead SOIC (R-14)
14-Lead TSSOP (RU-14)
θJA
172.92
112.38
141.9
88.2
114
θJC
61.76
61.6
43.7
56.3
23.3
Unit
°C/W
°C/W
°C/W
°C/W
°C/W
POWER SEQUENCING
The op amp supply voltages must be established simultaneously
with, or before, any input signals are applied. If this is not
possible, the input current must be limited to 10 mA.
ESD CAUTION
Rev. 0 | Page 5 of 16