TIMING SPECIFICATIONS (CL = 20 pF, AVDD = DVDD = DRVDD = 3 V, fCLI = 12 MHz, unless otherwise noted.)
Parameter
Symbol
Min
Typ
Max
MASTER CLOCK, VCKM
VCKM Clock Period
VCKM High/Low Pulsewidth
Delay from VCKM Rising Edge to Internal Pixel Position 0
AFE CLAMP PULSES1
CLPOB Pulsewidth2
tCONV
tVCKMDLY
83.33
2
41.67
9
20
AFE SAMPLE LOCATION1 (See Figure 13)
SHP Sample Edge to SHD Sample Edge
tS1
DATA OUTPUTS
Output Delay from VCLK Rising Edge
tOD
Pipeline Delay from SHP/SHD Sampling (See Figure 40)
33.34
41.67
9
9
SERIAL INTERFACE
Maximum SCK Frequency
SLD to SCK Setup Time
SCK to SLD Hold Time
SDA Valid to SCK Rising Edge Setup
SCK Falling Edge to SDA Valid Hold
SCK Falling Edge to SDA Valid Read
fSCLK
10
tLS
10
tLH
10
tDS
10
tDH
10
tDV
10
NOTES
1Parameter is programmable.
2Minimum CLPOB pulsewidth is for functional operation only. Wider typical pulses are recommended to achieve good clamp performance.
Specifications subject to change without notice.
Unit
ns
ns
ns
Pixels
ns
ns
Cycles
MHz
ns
ns
ns
ns
ns
ABSOLUTE MAXIMUM RATINGS
Parameter
With
Respect
To
Min Max
Unit
AVDD
AVSS –0.3 +3.9
V
TCVDD
TCVSS –0.3 +3.9
V
HVDD
HVSS –0.3 +3.9
V
RSVDD
RSVSS –0.3 +3.9
V
DVDD
DVSS –0.3 +3.9
V
DRVDD
DRVSS –0.3 +3.9
V
RS Output
RSVSS –0.3 RSVDD + 0.3 V
H1(A–D), H2(A, B)Output HVSS –0.3 HVDD + 0.3 V
Digital Outputs
DVSS –0.3 DVDD + 0.3 V
Digital Inputs
DVSS –0.3 DVDD + 0.3 V
SCK, SLD, SDA
DVSS –0.3 DVDD + 0.3 V
VRT, VRB
AVSS –0.3 AVDD + 0.3 V
CCDIN
AVSS –0.3 AVDD + 0.3 V
Junction Temperature
150
°C
Lead Temperature, 10 sec
350
°C
PACKAGE THERMAL CHARACTERISTICS
Thermal Resistance
␪JA = 24.9°C/W
ORDERING GUIDE
Model
AD9937KCP
Temperature
Range
–25°C to +85°C
AD9937KCPRL –25°C to +85°C
Package
Description
Lead Frame
Chip Scale
Package
(LFCSP)
Lead Frame
Chip Scale
Package
(LFCSP)
Package
Option
CP-56
CP-56
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD9937 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
REV. 0