English
Language : 

AD8190_15 Datasheet, PDF (5/24 Pages) Analog Devices – 2:1 HDMI/DVI Switch with Equalization
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Rating
AVCC to AVEE
3.7 V
DVCC to DVEE
3.7 V
DVEE to AVEE
VTTI
VTTO
AMUXVCC
Internal Power Dissipation
High Speed Input Voltage
High Speed Differential
Input Voltage
±0.3 V
AVCC + 0.6 V
AVCC + 0.6 V
5.5 V
4.62 W
AVCC − 1.4 V < VIN < AVCC + 0.6 V
2.0 V
Low Speed Input Voltage
I2C Logic Input Voltage
Storage Temperature
Range
Operating Temperature
Range
Junction Temperature
DVEE − 0.3 V < VIN < AMUXVCC + 0.6 V
DVEE − 0.3 V < VIN < DVCC + 0.6 V
−65°C to +125°C
−40°C to +85°C
150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
AD8190
THERMAL RESISTANCE
θJA is specified for the worst-case conditions: a device soldered
in a 4-layer JEDEC circuit board for surface-mount packages.
θJC is specified for the exposed pad soldered to the circuit board
with no airflow.
Table 3. Thermal Resistance
Package Type
θJA
56-Lead LFCSP
27
θJC
Unit
2.1
°C/W
MAXIMUM POWER DISSIPATION
The maximum power that can be safely dissipated by the
AD8190 is limited by the associated rise in junction tempera-
ture. The maximum safe junction temperature for plastic
encapsulated devices is determined by the glass transition
temperature of the plastic, approximately 150°C. Temporarily
exceeding this limit may cause a shift in parametric performance
due to a change in the stresses exerted on the die by the package.
Exceeding a junction temperature of 175°C for an extended
period can result in device failure. To ensure proper operation,
it is necessary to observe the maximum power derating as
determined by the coefficients in Table 3.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. 0 | Page 5 of 24