English
Language : 

AD590KF Datasheet, PDF (5/16 Pages) Analog Devices – 2-Terminal IC Temperature Transducer
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Forward Voltage ( E+ or E−)
Reverse Voltage (E+ to E−)
Breakdown Voltage (Case E+ or E−)
Rated Performance Temperature Range1
Storage Temperature Range1
Lead Temperature (Soldering, 10 sec)
Rating
44 V
−20 V
±200 V
−55°C to +150°C
−65°C to +155°C
300°C
1 The AD590 was used at −100°C and +200°C for short periods of
measurement with no physical damage to the device. However, the absolute
errors specified apply to only the rated performance temperature range.
Applicable to 2-lead FLATPACK and 3-pin TO-52 packages only.
AD590
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Rev. G | Page 5 of 16